Astria Fireplaces Acadia18MN Скачать руководство пользователя страница 2

www.Astria.US.com

126891-01A

2

SAFETY

TABLE OF CONTENTS

Safety .................................................................. 2

Local Codes......................................................... 4

Product Identification

 ........................................... 4

Unpacking............................................................ 5

General Information ............................................. 5

Installation ........................................................... 5

Operation ........................................................... 10

Inspecting Burners..............................................11

Cleaning and Maintenance ................................ 12

Troubleshooting ................................................. 13

Specifications

 .................................................... 15

Wiring Diagram .................................................. 15

Technical Service............................................... 15

Parts .................................................................. 16

Replacement Parts ............................................ 18

Accessories ....................................................... 18

Warranty ............................................................ 19

 WARNING: Improper instal-

lation, adjustment, alteration, 

service or maintenance can 

cause injury or property damage. 

Refer to this manual for correct 

installation and operational 

procedures. For assistance or 

additional information consult 

a qualified installer, service 

agency or the gas supplier.

 WARNING: This appliance 

is for installation only in a 

solid-fuel burning masonry or 

UL127  factory-built  fireplace, 

constructed of noncombstible 

material and connected to a 

working  flue.  (See  page  6  for 

minimum flue opening.

 WARNING: This is a gas-

fired heater. It uses air (oxygen) 

from the room in which it is in-

stalled. Provisions for adequate 

combustion and ventilation air 

must be provided. Refer to the 

National Fuel Gas Codes, ANSI 

Z233.1/NFPA 54, Air for Combus-

tion and Ventilation.

This appliance may be installed 

in an aftermarket,* permanently 

located, manufactured (mobile) 

home, where not prohibited by 

local codes.
This appliance is only for use 

with the type of gas indicated on 

the rating plate. This appliance 

is not convertible for use with 

other gases. 

* Aftermarket: Completion of sale, not for 

purpose of resale, from the manufacturer

State  of  Massachusetts:  The 

installation must be made by a 

licensed  plumber  or  gas  fitter 

in  the  Commonwealth  of  Mas

-

sachusetts.

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

 WARNING: Keep flue open 

when operating unit.

IMPORTANT:  Read  this  owner’s 

manual carefully and completely 

before trying to assemble, operate 

or service this log set. Improper 

use of this log set can cause seri-

ous injury or death from burns, 

fire,  explosion,  electrical  shock 

and carbon monoxide poisoning.

f i r e - p a r t s . c o m

Содержание Acadia18MN

Страница 1: ...54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of...

Страница 2: ...in which it is in stalled Provisions for adequate combustion and ventilation air must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA54 AirforCombus tion and Ventilation This applia...

Страница 3: ...gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted WARNING Donotallowfans toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame p...

Страница 4: ...ored under dusty conditions 9 Do not burn solid fuel in the fireplace after installing the log set Do not use this log set to cook food or burn paper or other objects 10 Log set becomes very hot when...

Страница 5: ...ing a power outage These log sets come with a Floor Media Kit included This kit is used to blend the floor and the log set together for a more natural look INSTALLATION WARNING A qualified ser vice pe...

Страница 6: ...r must be fixed open to provide a minimum of 29 square inch flue opeining at all times during operation of the log set A damper clamp can be used to secure the damper see Accessories page 18 See the N...

Страница 7: ...hook up NPT tap must be upstream from log set see Figure 4 Propane LP Supply Tank External Regulator Figure 4 Gas Connection Purchase the optional shutoff valve from your dealer Minimum inlet pressure...

Страница 8: ...NING Never use an open flame to check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Te...

Страница 9: ...er ports and valve access are not blocked see Figure 8 Retain a small amount of lava rock to be used in step 4 2 Place ember flake material around front and sides of unit close to but NOT on the burne...

Страница 10: ...service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS NOTICE During initial operation the appl...

Страница 11: ...s in display window of transmitter remote Press up or down key to change set temperature 6 To set delay timer pressTIMER button followed by either the up or down key 7 To change the flame height press...

Страница 12: ...bedding material etc Only limited cleaning will be required under normal use of this appliance Dust the front grate and top of receiver valve Do not use cleaning fluids to clean logs or any other par...

Страница 13: ...d service and repair heater IMPORTANT Valve system troubleshooting should only be accom plished by a qualified service technician Note Before troubleshooting the gas control system be sure external ga...

Страница 14: ...ht and secure 1 Check thermopile with mil livolt meter Take reading at thermopile terminals of gas valve It should read 325 millivolts minimum Replace faulty thermopile if reading is below specified m...

Страница 15: ...p Inlet Pressure Tap Piezo Gas Control Knob Pilot Adjustment Screw Pilot Burner Assembly Pilot Tube Thermopile Leadwires Local and Remote Switch REMOTE CONTROL MILLIVOLT POWER SUPPLY PROVIDE DISCONNEC...

Страница 16: ...6891 01A 16 PARTS 1 3 7 6 5 4 2 8 9 10 12 13 17 15 16 11 BlueRidge18MN BlueRidge18MP BlueRidge24MN BlueRidge24MP Acadia18MN Acadia18MP Acadia24MN Acadia24MP Sequoia18MN Sequoia18MP Sequoia24MN Sequoia...

Страница 17: ...ce 1 7 115449 01 Grate 1 115448 01 Grate 1 8 104489 01 Gasket 1 9 115491 01 Air Shutter 1 115492 01 Air Shutter 1 115493 01 Air Shutter 1 10 115454 01 Venturi 1 115454 02 Venturi 1 11 115452 01 Valve...

Страница 18: ...ctioning purchase date Usually we will ask you to return the part to the factory Purchase these accessories from your local dealer If they can not supply these accessories call INNOVATIVE HEARTH PRODU...

Страница 19: ...uce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damag...

Страница 20: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...

Страница 21: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Страница 22: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Страница 23: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Страница 24: ...126891 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126891 01 fire parts com...

Отзывы: