SPECIFICATIONS
Btu (Variable)
45,000/67,000 43,000/65,000 41,000/56,000 42,000/51,000
Type Gas
Natural Gas Only Propane/LP Only
Natural Gas Only
Propane/LP Only
Ignition
Piezo
Piezo
Piezo
Piezo
Manifold Pressure 3.5" - 1.6"W.C. 10" - 6.3"W.C. 3.5" - 1.6"W.C. 10" - 6.3"W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5" W.C.
13" W.C.
10.5" W.C.
13" W.C.
Minimum*
5.0" W.C.
11" W.C.
5.0" W.C.
11" W.C.
Valve Operation RF Millivolt
RF Millivolt
RF Millivolt
RF Millivolt
Orifice Size
#21
#42
#28
#45
* For purpose of input adjustment
WIRING DIAGRAM
Outlet
Pressure
Tap
Inlet
Pressure
Tap
Piezo
Gas Control
Knob
Pilot
Adjustment
Screw
Pilot
Burner
Assembly
Pilot Tube
Thermopile
Leadwires
Local and
Remote Switch
REMOTE CONTROL
(MILLIVOLT)
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
Figure 16 - Millivolt System Wiring Diagram
TECHNICAL SERVICE
You may have further questions about instal
-
lation, operation, or troubleshooting. If so,
contact INNOVATIVE HEARTH PRODUCTS
at 1-800-655-2008. When calling please
have your model and serial numbers of your
heater ready.
You can also visit INNOVATIVE HEARTH
PRODUCT’s web site at
www.IHP.US.com
.
BlueRidge24MN
Acadia24MN
Sequoia24MN
BlueRidge24MP
Acadia24MP
Sequoia24MP
BlueRidge18MN
Acadia18MN
Sequoia18MN
BlueRidge18MP
Acadia18MP
Sequoia18MP
f i r e - p a r t s . c o m