Inst 276 - Viron Connect Pool & Spa Controller V0610
13
Viron 3 Speed Pump Requirements
The Viron Connect controller is capable of controlling all aspects of the Viron P300 pump. Pumps with
manufacture dates after 1
st
March 2010 are compatible with the Viron Connect control system. To configure the
P300 pump to operate on the control system, you must switch the controls to Fast Comms. This is done by;
Switch on power to the Viron P300 pump.
Within 2 seconds of powering the pump up, press and hold in the medium speed button.
While holding in the medium speed button, press and release the high speed button.
Release the medium speed button.
To confirm you have configured the pump correctly, switch the pump off and wait 30 seconds. Power the
pump back on and within 2 seconds, press and hold the medium speed button. The LED next to the
medium button should be flashing and the LED next to the high speed button should be constant on. If not,
repeat process above.
VX “S” Series Salt Chlorinators
To configure the VX series salt chlorinators into Fast Comms;
Power unit up in normal stand alone mode.
With unit powered, press and hold in chlorine increase and decrease output buttons.
While holding in chlorine output buttons, press and hold in Pool Mode button
Release chlorine output buttons
Release Pool Mode button
Unit will display “Installer Mode – Press Backwash”
Press backwash button
Use Pool Mode and Spa Mode buttons to select SYSTEM setting
Press backwash button
Use Pool Mode and Spa Mode buttons to select Fast Comms setting
Press backwash button
RolaChem Chemical Dosing Systems
To configure the RolaChem RC8 to Fast Comms;
Through the MAINT option, enter installation mode.
In the installation menu, scroll through options until timer option
Select timers DISABLED
Select G4 system INSTALLED
Select Fast Comms ENABLED