If you have a salt  chlorinated  INDOOR pool or COVERED pool be very careful of the level of 
Chlorine being produced.  If you use a salt chlorinated spa be very careful of the level of Chlorine 
as the Chlorinator is usually sized for the pool and therefore should be switched off when heating 
the spa.    Leaving the chlorinator on can raise the chlorine level very rapidly in a small volume of 
water. 
 
These comments are intended as a guide only and are not definitive answers or recommendations 
on  pool  water  chemistry.    Astral  Pool’s  intention  is  to  provide  a  little  understanding  of  the 
potential  problems  of  water  chemistry  and  the  dangers  of  corrosion  to  heaters  (and  other  pool 
equipment and fittings). 
 
YOUR  WATER  SHOULD  BE  ADJUSTED  &  BALANCED  PRIOR  TO  ANY  CORRODED 
PARTS BEING REPLACED. 

 

 

 

DIGITAL THERMOSTAT OPERATION 

 

DESCRIPTION 

The  sophisticated  digital  thermostat  provides  temperature  read  out,  set  point  temperature, 
operating status of the heater and any fault conditions. 
 
TEMPERATURE DISPLAY 

The temperature display indicates water temperature in the inlet of the heater.  Therefore the pump 
must be operating for an accurate pool or spa water temperature to be displayed. 
 
Comfortable  pool  temperature  is  between  26

˚

C  and  30

˚

C.    Normal  spa  temperature  is  between 

36

˚

C and 38

˚

C.  To select your desired temperature press the up or down button repeatedly until 

the desired temperature is reached. 
 
To prevent rapid cycling of the heater, the thermostat has an inbuilt time delay which prevents the 
heater from turning on for two minutes after the set point has been reached.   If the time delay is 
activated, the symbol “L” will be displayed on the LCD screen on the front of the heater. This is 
part of normal operation. 
 
Should  a  fault  condition  occur,  the  heater  will  lock  out  and  prevent  further  heating.    A  lock  out 
condition is indicated by the symbols F0 to F9.  To reset a lock out condition, turn the power off 
for five seconds. 
 
When the water temperature is heated to within 1 degree of the thermostat set point, the Viron 
burner will modulate or turn down so that the set point is accurate maintained and not exceeded.    
This prevents waste of energy typically associated with on/off burners.    In addition, the set point 
is maintained very accurately, so the when using your spa pool, you will notice very little variation 
in water temperature.

Содержание Viron 250

Страница 1: ...fications subject to change without notice Melbourne Ph 03 9765 9700 Fax 03 9765 9770 Sydney Ph 02 9853 2100 Fax 02 9853 2170 Brisbane Ph 07 3308 5400 Fax 07 3309 5470 Gold Coast Ph 07 5552 2600 Fax 0...

Страница 2: ...Instructions 8 Winter Operation 8 Installation Installation Instructions 9 Flow Rates 9 Water Connections 9 Plumbing Diagram 9 Heater Dimensions 10 Indoor Installation 10 Clearances 10 Electrical Con...

Страница 3: ...n This appliance must be installed in accordance with the installation instructions local gas fitting regulations Standards Australia Installation Code AS5601 and any other relevant statutory authorit...

Страница 4: ...to appliance 3 This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand 4 Wait five minutes to clear out any gas If you then smel...

Страница 5: ...tancy of a well maintained pool spa heater is between 5 and 12 years The addition of sanitisers Chlorine Bromine etc and other water balancing and conditioning chemicals can increase the rate of wear...

Страница 6: ...the inlet of the heater Therefore the pump must be operating for an accurate pool or spa water temperature to be displayed Comfortable pool temperature is between 26 C and 30 C Normal spa temperature...

Страница 7: ...heater off then on again F2 Mechanical Hi Limit greater Allow water to cool below 30 C than 45 C or 55 C turn heater off then on again F3 Thermistor fault Phone for Service F4 N A F5 N A F6 Flue tempe...

Страница 8: ...ill help prevent insects nesting in the unit and ensure extended life and reliability of your heater 4 Have your heater professionally inspected at least every 2 years WINTER OPERATION If the pool won...

Страница 9: ...e fitted WATER CONNECTIONS The heater should always be installed after the pump and filter The water connections are located on the right hand side of the heater The inlet and outlet are clearly marke...

Страница 10: ...tion at reduced clearances as below Outdoor Clearances from non combustible surfaces are Front 300mm Both sides 300mm Rear 50mm Above 1000mm Outdoor Clearances from combustible surfaces are Front 300m...

Страница 11: ...operate only when the circulating pump is operating The pressure switch is designed to operate with the heater installed up to 3 metres above or below the surface level of the pool or spa It is impera...

Страница 12: ...r It is imperative that the heater is installed so that it does not operate when the circulating pump stops Recommended methods to achieve this are a Correct adjustment of internal pressure switch Ens...

Страница 13: ...Kit can be purchased separately and installed so that the condensate is returned into the pool water When the heater commences operation a solenoid valve will open the condensate line and allow the va...

Страница 14: ...heater is running adjust gas ratio screw to achieve a CO ratio of between 30ppm to 60 ppm for Natural Gas models and between 50ppm and 150ppm for model 250 ULPG 14 Check meter gas usage rate to ensure...

Страница 15: ...ion displayed Refer to fault indication table Gas turned off Turn gas cock on Heater in a Fault condition Refer to fault indication table HEATER SHORT CYCLING RAPID ON AND OFF OPERATION Possible cause...

Страница 16: ...pipe with average number of fittings Model 20 mm 25 mm 32 mm 40 mm 50 mm VIRON 250 6 m 25 m 90 m 240 m 320 m VIRON 350 3 m 14 m 45 m 110 m 320 m VIRON 450 2 m 8 m 25 m 70 m 300 m VIRON 550 6 m 18 m 4...

Страница 17: ...Viron Pool and Spa Heater Page 17 VIRON WIRING DIAGRAM...

Страница 18: ...The warranty shall not apply to any heaters or parts which have been subject to accident negligence alteration abuse or misuse Corrosion of the heat exchanger is caused by improper water chemical bal...

Отзывы: