Viron Pool and Spa Heater
Page 7
DISPLAY SYMBOL INDICATION
Under fault conditions the thermostat will display a set of alpha numeric symbols to indicate the
status of the heater. The meaning of each symbol and action to be taken are listed as follows:
SYMBOL
MEANING
ACTION
Temp Display
Unit has power.
No action.
F0
Heater locked off, thermistor
If water temperature reads
wire disconnected or water
greater than 0
°
C, phone for
at 0
°
C (freeze conditions).
service.
F1
Thermostat reads greater
Allow water to cool below 40
°
C ,
than 45
°
C.
turn heater off then on again.
F2
Mechanical Hi Limit greater
Allow water to cool below 30
°
C,
than 45
°
C. or 55
°
C
turn heater off then on again.
F3
Thermistor fault
Phone for Service
F4
N/A
F5
N/A
F6
Flue temperature safety device
Phone for Service
locked out due to overtemperature
F7
Condensate drain blocked
Phone for Service
F8
Heat exchanger sensor fault
Phone for Service
F9
Heat exchanger sensor too hot
Phone for Service
Greater than 240degC
L
Heater locked out on time
No action. Heater will
delay for 2 minutes.
Automatically reset after
time delay.
time delay.
Pump operating & sufficient
No action.
water pressure to operate heater
Thermostat calling for heat.
No action.
Electronic Flame Supervision
operating.
Burner Operating
No Action