TABLE 1: TECHNICAL DATA [OPTIMA CHILLER]
OPTIMA CHILLER
7 KW
15 KW
15 KW
CODES
45694
45696
45696-3
POWER SUPPLY
230 V / 50 Hz / I+N
230 V / 50 Hz / I+N 400 V / 50 Hz / III+N
CONDENSER
TITANIUM
COMPRESSOR
SCROLL
FANS
UNITS
Uds.
1
1
1
TYPE
AXIAL
FLOW
m
3
/h
5500
7000
REFRIGERANT GAS R-407-C
KG
2,5
3,5
WATER FLOW
m
3
/h
12
16
CONNECTION DIAMETER
mm
50
50
Air = 5 °C
Water = 24 °C
70% Hr
INLET POWER
kW
1,49
2,92
OUTLET POWER
kW
6,37
12,59
COP
4,28
4,31
Air = 15 °C
Water = 24 °C
70% Hr
INLET POWER
kW
1,81
3,52
OUTLET POWER
kW
8,92
16,00
COP
4,93
4,55
Air = 27 °C
Water = 24 °C
70% Hr
INLET POWER
kW
1,98
3,88
OUTLET POWER
kW
9,95
19,40
COP
5,03
5,00
CHILLER MODEL
Air = 30 °C
Water = 24 °C
70% Hr
INLET POWER
kW
1,95
3,88
OUTLET POWER
kW
9,19
15,72
EER
4,71
4,05
Air = 35 °C
Water = 24 °C
70% Hr
INLET POWER
kW
2,21
4,26
OUTLET POWER
kW
8,56
14,70
EER
3,87
3,45
SOUND
PRESSURE
dbA (d*)
70
70
dbA (5 m)
65
65
GROSS WEIGHT
kg
123
140