OPTIMA / MAYA SERIES · HEAT PUMP AIR/WATER
© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
Pag: 36
ENGLISH
•
Press
to pass through all the periods and exit the menu.
NOTE: If the Schedule Program mode is activated and there are no periods scheduled, the
machine will not start.
5.
Setting the machine operating mode
•
Press
to choose the machine operating mode (Heat, Cool and Automatic, only if
F29=3).
•
Press
for at least 2 seconds to activate or deactivate the Schedule Programming
mode.
6.
Checking the temperatures (Reading variables)
•
Press
to display the temperature probe settings and compressor consumption
(3 settings for each phase of the compressor). Use
or
to display the various
settings.
The values shown refer to the following nomenclature:
T1
T2
T3
T4
T5
T6
Water inlet
temperature
.
Cool sensor 1
(Defrost Probe)
Compressor 1
discharge
temperature
Sonda de
Aspiración 1
Cool sensor 2
(Defrost Probe)
Discharge
probe 2
T7
T8
T9
T10
T11
T12
Aspiration
Probe 2
Ambient
temperature
Water outlet
temperature
Valve steps
circuit 1
Valve steps
circuit 2
High Pressure
circuit 1 (BAR)
HP1
T13
T14
T15
T16
T17
T18
Low Pressure
circuit 1 (BAR)
LP1
High Pressure
circuit 2 (BAR)
HP2
Low Pressure
circuit 2 (BAR)
LP2
Current
phase 1-
compressor 1
Current
phase 2-
compressor 1
Current phase
3-compressor
1
T19
T20
T21
Current Phase
1-compressor 2
Current phase
2-compressor 2
Current phase.
3-compressor 2
NOTE: The compressor consumption settings vary depending on water and outside
temperature and the settings of phase consumptions does not have to be the same.