12.
PREVENTIVE MAINTENANCE
You must keep a record of each component maintained as well as the actions or repairs
undertaken.
•
DISCONNECT THE EQUIPMENT FROM THE POWER SUPPLY before performing any
maintenance procedures.
•
The surface of the exterior panels may be cleaned with a soft cloth and non-abrasive
cleaner.
•
The machine has been designed to operate outdoors.
•
It is important that the equipment be installed on stable ground and protected from
flooding.
Things to take into account:
EVAPORATOR COIL:
The evaporator coil should be kept clean and free of obstacles which may hinder the circulation
of air through them. In order to clean it, use water at low pressure and non-abrasive detergents
or cleaning liquids made specifically for that purpose.
COMPRESSOR:
Compressor oil must be checked in those unit models provided with an oil viewer.
Make sure the crankcase heater works properly.
Verify that the compressor refrigerates adequately with the circulating gas (verify the refrigerant
charge).
Verify that the power consumption has not increased.
Verify that the compressor discharge pressure is not too high and that the intake pressure is not
too low.
Verify that the compressor fasteners are not deteriorated.
Verify that no frost develops on the compressor.
CONDENSER:
When the installation is going to stand for long periods of time, it is advisable to remove
the equipment from the installation or periodically ventilate the room where it is located.
This is due to the humid and chlorinated environment to which the equipment is
exposed, which causes the accelerated deterioration of its electronic components. The
guarantee does not cover those cases in which the product is damaged by prolonged
exposure to a humid and chlorinated environment