![Astoria Core600 AL Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/astoria/core600-al/core600-al_use-and-maintenance-manual_2990329045.webp)
USER Manual
45
of
216
English
6.3.3
Electric heating for the DISPLAY
version
• Press the machine's main
switch (
2
).
•
Wait another second or so for the automatic test to be
carried out.
XPV35 XXXX
Controller Board
FW ver. 01.09
FW ver. 1.15
•
Wait for the water in the heating unit to be automatically
refilled, if this is necessary. This will be shown on the dis
-
play.
48
°C
The heating unit
is being filled with
water (yellow colour)
Heating-up phase
•
Wait a few moments for the machine to fully heat up.
53
°C
Heating unit water OK
Heating-up phase
• If the timeout intervenes, a red flashing warning will ap
-
pear on the display.
Flashing
red colour
Flashing
yellow colour
6.3.4
Gas heating
(if a gas system has been installed)
•
Turn the power switch (
A
) to position 1.
• Open the gas valve (
B
) on the mains.
•
Hold down the (
C
) button and, at the same time, press
the ON button (
D
). Once the flame ignites, hold down the
knob (
C
) for a few seconds, to allow the thermocouple to
activate correctly.
• Then check that the flame has ignited through the win
-
dow (
E
).
•
Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
D
A
B
C
E
6.3.5
El gas heating
(if a gas system has been installed)
•
Proceed as indicated in the previous paragraph.
• After checking that the flame has ignited, turn the power
switch (
A
) to position 2. In this way the heating unit's
heating element is powered and the operating pressure
will be reached more quickly.
•
Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
6.3.6
Turning the machine off
Turn off the machine using the main switch or power switch.
2
Содержание Core600 AL
Страница 215: ......