Profile Series v.G1.5/LK Mortise Lock      

Hardwiring options include one or a combination of Forced/Propped Door, Hard Power and/or Remote  

Unlock (REX). Refer to the examples on the following pages: 

1.  Forced/Propped Door Option (DM-).  

2.  Hard Power and Remote Unlock (91-). 
3.  Hard Power and Remote Unlock (-91), with Forced Propped Door (DM-). 

Important

1.  Caution: Disconnect all input power before beginning installation to prevent electrical shock and  

equipment damage.

2.  Installer must be a trained, experienced service person.
3.  All wiring must comply with applicable local electrical codes, ordinances and regulations.

Installation Notes

1.  With new applications, an ElectroLynx® door harness with 8 and 4 pin connectors will be  

pre-installed inside door by ASSA ABLOY door manufacturer when specified during ordering process.

2.  Wiring to pigtail harness is per facility wiring requirement.

ElectroLynx® connector terminations and wire colors all match.

3.  If door does not have an ElectroLynx® type door harness, cut connectors off product and hard-wire,  

or consult factory for appropriate mating harness.

ElectroLynx®

As part of their promise to provide innovative, fast and effective, and higher security

solutions to their customers, ASSA ABLOY Group companies offer ElectroLynx, a

universal quick-connect system that simplifies the electrification of the door opening.

ElectroLynx® is a registered trademark of ASSA ABLOY, Inc.

Locking Mechanism

Plug

Receptacle

ElectroLynx® Connector System Notes

The system is designed to be installation friendly with connectors  

from the electric hinge through the door to the rail. The only wiring 

required is to the loose wires on the pigtail harness  

assembly on the frame side of the electric hinge.

IMPORTANT

:

The plug and receptacle connectors are designed to mate and lock 

together as shown in the figure. Plug the connectors into each other 

with the locking mechanism aligned as indicated.
Do NOT force connectors on any other way.

Wiring Options

8

Содержание SARGENT Profile v.G1.5/LK

Страница 1: ...acturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Profile LK Morti...

Страница 2: ...se harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol...

Страница 3: ...ded Easily field reversible without disassembling the lock body Case 12 gauge heavy duty wrought steel 3 4 2 Outside lever controlled by any combination of keypad proximity or RF technology Inside lev...

Страница 4: ...acturing Company is prohibited 01 31 14 Profile Series v G1 5 LK Mortise Lock 5 Parts Breakdown 35 2 800 810 WIRE 9473 www sargentlock com A7855B Profile Series v G1 5 05 04 09 A7855 B 11 11 27 28 29...

Страница 5: ...92 Inside Escutcheon Housing Only without Thumb Turn 1 82 0494 Inside Escutcheon Housing Only with Thumb Turn 1 52 2440 100 LK User Key Pad Controller Assembly 1 52 2783 2000 G1 LU User Controller Ass...

Страница 6: ...ining the door hand B Prepare Door Prep door according to Instruction Sheet A7454 and appropriate template Manufacturer Door Template 4632 Through bolt Hole Outside Cylinder Hole 76 and 78 Functions L...

Страница 7: ...the screwdriver 90 to push latchbolt out until back of bolt clears lock case front 3 Rotate latchbolt 180 until the latchbolt drops back into the lock body Note Latch cannot be unscrewed Latchbolt Spa...

Страница 8: ...r to template for fire stop prep locations 2 Attach with flap up and out using 2 8 x 1 2 self tapping screws for wood and metal doors B Weather Conduit P N 52 2847 Install weather conduit on NON FIRE...

Страница 9: ...ecting the mounting posts through the door and lock body Fig 6B 3 Make certain the lever spindle is properly engaged in lock 4 On the inside of the door insert spindle into square hole of mortise lock...

Страница 10: ...en mounted Fig 7A 2 Attach the ground wire to the bottom of the controller assembly E1 Fig 7A 3 Connect the cable from the cylindrical lock to the bottom of the controller assembly TB1 Fig 7B If Hardw...

Страница 11: ...ylinder through the spring and rosette collar and screw into lock body rotating the cylinder clockwise Fig 9A Cylinder should be flush with rosette collar Note The 43 cylinder may be used when install...

Страница 12: ...ws through top and bottom of the escutcheon Fig 11A Thread into outside escutcheon Note For RF Technology versions G1 TU G1 TP G1 TA refer to RF Technology Lock section on page 14 to install through b...

Страница 13: ...ll and Remove Batteries A Install Batteries and Keeper 1 Place 6 AA batteries into the compartment being careful to properly align polarity Fig 12A 2 To install battery keeper insert the tabs on the b...

Страница 14: ...ition The antenna board must be carefully moved to access the upper through bolt screw Care should be taken to prevent damage to the antenna retaining tabs during this process Fig 7A 1 Press the two t...

Страница 15: ...door manufacturer when specified during ordering process 2 Wiring to pigtail harness is per facility wiring requirement ElectroLynx connector terminations and wire colors all match 3 If door does not...

Страница 16: ...tch eon along the battery keeper back under the bottom opening between the controller and escutcheon and attach at the bottom of the controller Note Connectors go on only one way Do not offset connect...

Страница 17: ...d Propped harness and hard wire to non ElectroLynx two conductor door harness b DM requires two conductors c Hard wire door harness to power transfer device d Hard wire door status switch to power tra...

Страница 18: ...uires two conductors c Hard wire door harness to power transfer device d Hard wire door status switch to power transfer device IMPORTANT 6 AA batteries MUST be removed from controller when using 3267...

Страница 19: ...to power transfer device d Hard wire door status switch to power transfer device IMPORTANT 6 AA batteries MUST be removed from controller when using 3267 power supply Ground Tab E3 TB2 Remote Power U...

Страница 20: ...es with cylinders insert key into cylinder and rotate Check to see if 1 The key retracts the latch Key should rotate freely Key should extend and retract the deadbolt if applicable 2 The inside lever...

Страница 21: ...800 810 WIRE www sargentlock com A7855C 21 Copyright 2014 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproductions in whole or in part without express written permis...

Страница 22: ...vation and replacement applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2014 Sargent Manufacturing Company an ASSA ABLOY Group c...

Отзывы: