PR100 Exit Devices
7 Install Door Position Switch (DPS)
1. Insert DPS into the raceway on the latch edge of the door.
2. Push wires through raceway toward lock prep.
3. Push DPS firmly into place by hand.
Note: DO NOT TAP SWITCH WITH ANY TOOL.
4. Install magnet into door frame. Push firmly into place by hand.
5. To connect DPS to lock controller per diagram, refer to the wiring in
Step #9.
8 Attach Gasket and Install Outside Escutcheon
For exterior applications, use a gasket between the escutcheon and out-
side door surface.
To apply weatherseal gasket:
1. Carefully remove the backing from the gasket (Fig. 8A).
2A. For 12- fire rated devices:
Feed keypad ribbon cable/connector
from outside of door through gasket and fire stop plate (Fig. 8B).
2B. For non-12- exit devices:
Feed keypad ribbon cable/connector
through the gasket and then through the conduit hole in door.
Note: Install ribbon cable with cable exiting down.
3. Apply gasket to escutcheon:
a. Starting in one place, press the adhesive
side of the gasket firmly against
the escutcheon.
b. Work around the escutcheon,
pressing the sticky side of the
gasket firmly against the
escutcheon edge.
c. The gasket should be aligned so
that all edges of the escutcheon
are covered.
4. Place against the outside escutcheon,
while directing mounting posts
through the door.
Fig. 7
Fig. 8A
Fire
Stop
Plate
Weatherseal
Gasket
Fig. 8B