16
Copyright © 2012, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
8/05/12
PR100 Exit Devices
Slide mortise lock into door and securely fasten with (2) flat head screws (Fig. 2).
2 Install Mortise Lock
1. For exterior applications, use ET gasket (52-0263) to seal
between ET escutcheon and outside door surface (Fig. 3).
2. Route ET harness through square wire cutout and out
other side of door.
3. Place ET control on door with spindle inserted
through mortise lock (Fig. 3).
3 Position Exit Trim
Showing Wood Door Template
Without Cylinder
ET gasket
(part number
52-0263)
Outside of Door
Fig. 3
Fig. 2
Outside of Door
Wood Door Template
With Cylinder
Lock Installation
B. Door Preparation
Prior to installation, all holes must be free of burrs, debris and sharp edges.
If doors are not properly reinforced per ANSI 115.2, commercially available
reinforcements should be installed.
Prep door using the following (available at www.intelligentopenings.com):
•
Exit installation instructions: A6705
•
Field Template: A7790
•
Door Manufacturer’s Template: 4641
1 Prepare Door
A. Verify Hand and Bevel of Door
•
Check handing of door; this device is not reversible.
•
Door should be fitted and hung.
•
Verify box label for size of exit device, function
and handing.
Inside
Outside
Left Hand
Reverse Bevel
LHRB
Right Hand
Reverse Bevel
RHRB
Fig. 1