background image

A8080D (N2)

8/12

Copyright 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. 

All rights reserved. Reproduction in whole or in part without the express written  

permission of Sargent Manufacturing Company is prohibited. 

PR100

with Aperio

 

Wireless Lock 

Technology

Exit Device

Installation Instructions

Содержание Sargent PR100

Страница 1: ...ompany an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited PR100 with Aperio Wireless Lock Technology Exit Device Installation Instructions ...

Страница 2: ...aratus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareillage numérique de la classe B répond à toutes les exigences de l interférence canad...

Страница 3: ...f keypad credential reader or mechanical cylinder The SARGENT PR100 lock with Aperio Technology makes it easy and cost effective to bring access control to additional doors It uses local wireless communication between the lock and an Aperio hub to connect to an access control system eliminating the greatest cost and inconvenience of traditional access control the wiring at the door The PR100 is av...

Страница 4: ...ions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited 8 05 12 PR100 Exit Devices Aperio with 8877 8878 Rim Exit Parts Breakdown for Aperio With 8877 8878 x ET x Lever Design 13 56 MHz iCLASS 125 kHz Prox 6 4 4 7 7 5 3 6 10 1 8 12 13 2 7 11 1a 14 12 9 10 ...

Страница 5: ...78 52 5320 Aperio Electronic Replacement Pack Prox only N2 PA 8877 52 5352 Aperio Electronic Replacement Pack Prox only N2 PA 8878 52 5323 Aperio Electronic Replacement Pack Prox and Keypad N2 PK 8877 52 5355 Aperio Electronic Replacement Pack Prox and Keypad N2 PK 8878 5 52 4340 Battery Cover Assembly 1 6 01 1212 Security Screw 1 7 52 2425 Profile Screw Pack Specify Finish Includes Fire Stop Plat...

Страница 6: ...e pre prepped Prep door using the following see website www intelligentopenings com Exit installation instructions A6770 Field Template A7992 shipped with product Door Manufacturer s Template 4640 Inside Outside Left Hand Reverse Bevel LHRB Right Hand Reverse Bevel RHRB Fig 1 2 Position Trim ET For exterior applications use ET gasket 52 0263 to seal between ET escutcheon and outside door surface F...

Страница 7: ...rim and Chassis 1 Route ET harness through wire run channel for wood doors Fig 3A and through access hole for metal doors not shown Note Make sure no wires are pinched 2 Engage ET spindle in the hub of exit device chassis 3 Secure chassis and ET with 2 1 4 20 x 2 3 8 flat head machine screws 4 Connect ET harness and connector from chassis Fig 3B 4 Inside of Door Inside of Door Fig 3A 1 3 5 Outside...

Страница 8: ...r so that the SARGENT logo is right side up Fig 5B Outside of Door Fig 5A 4 10 Wood or 10 24 Machine Screws 2 12 24 x 1 7 8 Correct Incorrect Fig 5B Inside of Door Fig 6A Fig 6B Ribbon Cable Hole Fig 6C O Ring Outside of Door 2 10 x 1 1 4 Screws for Wood and Metal Doors A Fire Stop Plate P N 52 0033 Fire rated doors require a fire stop plate on the outside of the door Fig 7A 1 For wood doors drill...

Страница 9: ...et between the escutcheon and out side door surface To apply weatherseal gasket 1 Carefully remove the backing from the gasket Fig 8A 2A For 12 fire rated devices Feed keypad ribbon cable connector from outside of door through gasket and fire stop plate Fig 8B 2B For non 12 exit devices Feed keypad ribbon cable connector through the gasket and then through the conduit hole in door Note Install rib...

Страница 10: ...cturing Company is prohibited 8 05 12 PR100 Exit Devices 9 Connect and Position Outside Escutcheon Wires Images shown represent installation without gasket If gasket is necessary refer to Step 8 Attach outside escutcheon reader cable to connector P1 on back side of inside escutcheon Outside of Door Inside of Door Fig 5B Fig 9 P1 TB1 Outside Escutcheon Reader Cable TB2 Reader Cable ...

Страница 11: ...e Escutcheon Fig 10 Fig 11 Inside of Door Inside of Door TB2 TB1 1 Insert 8 32 x 2 1 2 screws through inside escutcheon and thread into outside escutcheon 2 Tuck wires safely under space below controller assembly 3 Straighten escutcheons and tighten securely Fig 11 1 Connector RX harness 3 pin connector from ET Trim to chassis harness 2 Attach connector from ET to the controller assembly TB1 3 Con...

Страница 12: ... Place 6 AA batteries in the compartment being careful to align polarity properly Fig 13C 4 Replace battery keeper being careful to engage tabs at top to hold it in place Fig 13B 5 Attach battery cover to inside escutcheon making sure to line up tabs with retaining slots in battery cover Secure with the security screw and tool Fig 13A and 13D 6 Secure with security screw using tool in Fig 13D NOTE...

Страница 13: ...ions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited PR100 Exit Devices 14 Install Rail Assembly Fig 14 1 Connect RX harness 3 pin connector from the rail to the RX harness in the chassis 2 Attach rail assembly according to Exit Installation Instructions A6770 ...

Страница 14: ...n whole or in part without express written permission of Sargent Manufacturing Company is prohibited 8 05 12 PR100 Exit Devices Parts Breakdown for Aperio With 8977 8978 x ET x Lever Design 13 56 MHz iCLASS 125 kHz Prox 4 7 16 3 6 2 8 9 1 11 11 15 12 13 7 7 5 1a 14 10 10 9 4 Aperio With 8977 8978 Mortise Exit 7 ...

Страница 15: ... iCLASS and Keypad N2 IK 8978 52 5353 Aperio Electronic Replacement Pack Prox only N2 PA 8977 52 5354 Aperio Electronic Replacement Pack Prox only N2 PA 8978 52 5356 Aperio Electronic Replacement Pack Prox and Keypad N2 PK 8977 52 5357 Aperio Electronic Replacement Pack Prox and Keypad N2 PK 8978 5 52 4340 Battery Cover Assembly 1 6 01 1212 Security Screw 1 7 52 2525 Profile Screw Pack Specify Fin...

Страница 16: ...t Trim Showing Wood Door Template Without Cylinder ET gasket part number 52 0263 Outside of Door Fig 3 Fig 2 Outside of Door Wood Door Template With Cylinder Lock Installation B Door Preparation Prior to installation all holes must be free of burrs debris and sharp edges If doors are not properly reinforced per ANSI 115 2 commercially available reinforcements should be installed Prep door using th...

Страница 17: ... ET harness through wire route slot for wood doors Fig 4A and access hole for metal doors not shown Note Make sure no wires are pinched 2 Engage ET spindle in the hub of exit device chassis 3 Secure chassis and ET with 2 1 4 20 x 2 3 8 flat head machine screws 4 Connect ET harness and connector from chassis Fig 4B 4 Secure Inside Trim and Chassis Outside of Door Showing Wood Door Template With Cyl...

Страница 18: ...on exit chassis on door with lever arm under rear section of mortise lock 4 Secure chassis and ET with 2 1 4 20 x 2 3 8 flat head machine screws 4 10 Wood or 10 24 Machine Screws 6 Install Cylinder For devices without cylinders skip this section 1 Verify orientation of cylinder Fig 6A 2 Slide cylinder through ET trim and thread into the lock body rotating the cylinder clockwise Cylinder should res...

Страница 19: ...DPS through door Pull Out Slack Fig 8 7 Door Options A Fire Stop Plate P N 52 0033 Fire rated doors require a fire stop plate on the outside of the door Fig 7A 1 For wood doors drill 2 1 8 x 1 1 4 deep holes into the door For metal doors drill 2 9 64 x 1 1 4 deep holes into the door if not already present 2 Refer to template for fire stop prep locations 3 Attach fire stop plate with flap up and ou...

Страница 20: ...not shown Note Install ribbon cable with cable exiting down 3 Place the outside escutcheon against the door while directing mounting posts through the door 9 Install Gasket for Exterior Doors For exterior applications use a gasket between escutcheon and outside door surface To apply weatherseal gasket 1 Carefully remove the backing from the gasket Fig 9 2 Apply gasket to escutcheon a Starting in o...

Страница 21: ...gent Manufacturing Company is prohibited PR100 Exit Devices 11 Connect and Position Outside Escutcheon Wires Images shown represent installation without gasket If gasket is necessary refer to Step 9 Attach outside escutcheon reader cable to connector P1 on back side of inside escutcheon Outside of Door Inside of Door Fig 5B Reader Cable Fig 11 P1 Outside Escutcheon Reader Cable ...

Страница 22: ...ections 1 Connect RX harness 3 pin connector from ET Trim to chassis harness 2 Attach connector from ET to the controller assembly TB1 3 Connect DPS from switch to 3 pin connector of the harness connected to controller assembly TB2 13 Install Inside Escutcheon 1 Insert 2 8 32 x 2 1 2 screws through inside escutcheon and thread into outside escutcheon 2 Tuck wires safely under space below controlle...

Страница 23: ...ful to engage tabs on the top to hold it in place Fig 14B 5 Attach battery cover to inside escutcheon making sure to line up tabs with retaining slots in battery cover Fig 14D 6 Secure with the security screw using tool Fig 14D NOTE Ensure the tamper switch activator does not fall out of the cover during assembly Fig 14E 14 Install or Replace Batteries Fig 14A 1 Connect RX harness 3 pin connector ...

Страница 24: ...t Devices 1 Insert key into cylinder and rotate There should be no friction against lock case wire harness or any other obstructions 2 Check that the key retracts the latch The key should rotate freely 3 Present a valid iCLASS or 125 kHz prox credential to unlock outside lever and retract latch Note Refer to document ATMN01 Aperio Online Technology Reference Manual for instructions on programming ...

Страница 25: ...ery is not accepted as new after a power on reset 1 Lock Normal Operation LED indication 2 Lock Maintenence LED Indication Some special LED indication schemes are used during lock maintenance actions Enter configuration mode Five yellow flashes 125 seconds each Fig Lock maintenance LED indication Card read configurable Access granted EAC offline or online Access denied EAC online Access denied EAC...

Страница 26: ...ing table Blink Meaning if Red Code in Event Log 2 Main board firmware corrupt 0x0001 3 Override list corrupt 0x0002 4 Production data corrupt 0x0004 5 Security data corrupt 0x0008 6 Configuration data corrupt 0x0010 7 Battery power low 0x0020 8 RFID reader circuit error 0x0040 9 Voltage regulator error 0x0080 10 Card detection circuit error 0x0100 11 Secure area communication error 0x0200 12 Secu...

Страница 27: ...Notes The global leader in door opening solutions ...

Страница 28: ...e company s customer base includes commercial construction institutional and industrial markets Copyright 2012 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user n...