12.2
Office Function
You can use the Office function to override the always open time slot. Individual media (keys,
tags, cards) can additionally be authorised to execute the Office function.
12.2.1
Office/Load Function
The Office/Load function sets up the always open function not to start automatically in the
assigned time slot. The always open time slot is not activated until a defined and authorised
Office key (see 12.2.3) or Office master key (see 12.2.4) is held up to the reader module.
If the Office key or Office master key is again held up to the reader module before the end of the
active time slot, always open is reset and the handle is disengaged.
<<Apply conscious action>> means that the office master key, or the office key, must be pre-
sented at the reader module for at least two seconds to start or stop the always open time slot.
Æ
The time cannot be changed.
12.2.2
Decision logic of office function
Door
Key/
User
Officekey
Officemasterkey
Permanent
open time
frame
activ?
Permanent
open time
frame set?
Key in time
frame?
Access?
Permanent
open time
frame set?
Permanent
open time
frame
canceled?
Access?
Permanent
open time
frame set?
Permanent
open time
frame
canceled?
No
No
No
Æ
No
No
-
Æ
No
No
-
No
No
Yes
Æ
Yes
No
-
Æ
Yes
Yes
-
No
Yes
No
Æ
Yes *
-
No
Æ
Yes *
-
Yes
No
Yes
Yes
Æ
Yes
-
No
Æ
Yes
-
Yes
Yes
No
No
Æ
No
No
-
Æ
No
No
-
Yes
No
Yes
Æ
Yes
Yes
-
Æ
Yes
Yes
-
Yes
Yes
No
Æ
Yes *
-
No
Æ
Yes *
-
Yes
Yes
Yes
Yes
Æ
Yes
-
Yes
Æ
Yes
-