         14

Product

8 PIN CONNECTION

4 PIN CONNECTOR

1-Black

2-Red

3-White

4-Green

5-Orange

6-Blue

7-Brown

8-Yellow

1-Violet

2-Gray

3-Pink

4-Tan

ACCESS CONTROL DEVICES: Harmony H1 Mortise, ElectroLynx wire Color / Function assignments

12VDC 

Reader Power

WIE-

GAND

WIE-

GAND

RX (NO/

NC)

RX 

(COM)

EGND

LED

12 OR 24 VDC

(LOCK RELAY

DPS 

(NC)

DPS 

(COM)

SARGENT -

HARMONY 

SERIES,

H1 Mortise

NEG

POS

DATA_1

DATA_0

REF.

STEP 2A

REF.

STEP 

2A

REF.
DIA-

GRAMS

REF.
DIA-

GRAMS

NEG

POS

DPS

DPS

Reader LED Configuration

The Harmony Series reader can be configured for (3) modes of LED operation:

Mode 1:

• Red LED ‘ON’ when powered.
• Presenting a 125kHz proximity card will cause LED to ‘FLICKER’ Green and return to Red state.
• Reference Diagram #1.
   Note: LED wire is unconnected.

Mode 2:

• Green LED “ON” when powered.
• (No Flicker) after presenting valid 125kHz proximity card.
• Reference Diagram #2.
   Note: LED wire must be connected to circuit GROUND of the system’s power supply.

Mode 3:

• EAC Panel controls LED operation.
• Reference Diagram #3.
   Note: Control of LED is a function of the EAC panel equipment (ie. Relay) to toggle between Green & Red.
   Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or  

   door reader performance will be impacted (Ref. Diagram #3).

PIN8 (Yellow – LED)

PIN 6 (Blue – RX)

PIN 4 (Green – Data 0)

PIN 2 (Red – Reader POS)

PIN 1 (Black – Reader NEG)

PIN 3 (White – Data 1)

PIN 5 (Orange – RX)

PIN 7 (Brown)

PIN 4 (Tan – DPS)

PIN 2 (Gray – Lock POS)

PIN 1 (Violet – Lock NEG)

PIN 3 (Pink – DPS)

Wiring Diagrams

7

If your lock is configured with End of Line Resistors, reference instruction sheet A8191 for the wiring of 
RX & DPS outputs.

Содержание Harmony H1

Страница 1: ...anufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited HARMONY Mort...

Страница 2: ...nce to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reor...

Страница 3: ...A 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1 00...

Страница 4: ...of Sargent Manufacturing Company is prohibited 05 15 15 Harmony Series H1 Mortise Lock A7877F 800 810 WIRE 9473 www sargentlock com 4 Tools Required Phillips Screw Driver Standard size Slotted Screw D...

Страница 5: ...Adapter Plate And Bushing Assembly Dl 1 12 Reference Harmony Series Catalog For Available Lever Styles 1 13 Reference Harmony Series Catalog For Available Cylinders Size 43 1 14 Lock Body H1 82270 12...

Страница 6: ...e www intelligentopenings com Prior to installation make sure all holes are free of burrs debris and sharp edges If doors are not properly reinforced per ANSI 115 2 commercially available reinforcemen...

Страница 7: ...t face strike Fig 2B The deadlatch is self adjusting To change hand of latchbolt 1 Insert screwdriver into the spade shaped slot 2 Rotate screwdriver 90 to push latch out until back of latch clears lo...

Страница 8: ...n 4 Install appropriate hardware lock body screws NOTE Do not tighten screws completely at this time Cylinder should be installed prior to tightening Inside of Door 2 12 x 1 1 4 Long Flat Head Wood Sc...

Страница 9: ...the bottom Remove peel backing and place gasket on door Fig 6 6 Install Inside Gasket if necessary Required for exterior door applications Fig 6 Inside of Door Fig 5B Gasket required for exterior door...

Страница 10: ...inder before inserting into the escutcheon Fig 8B 3 Use the key to rotate the cylinder clockwise until it is flush at the bottom and the SARGENT logo is right side up Do not attempt to tighten all the...

Страница 11: ...ock body screws Fig 9B Fig 9A Mortise Lock body Screw 8 32 X 5 8 Phillips Oval Head and Lock Washer Machine Screw Mortise Lock body Screw 1 Connect P3 2 pin connector from lock body to J3 on interior...

Страница 12: ...g of wires when mounting escutcheon Fig 11B Do not tuck extra mortise lock body wires back inside the lock body cylinder hole Fig 11A Fig 11B Outside of Door 1 Tighten the inside escutcheon securely t...

Страница 13: ...the lock accepts either 12 or 24V we recommend a 12V power supply to support both the lock and reader with a single power supply is horizontal and facing the hinge side of the door Push lever onto sp...

Страница 14: ...peration Mode 1 Red LED ON when powered Presenting a 125kHz proximity card will cause LED to FLICKER Green and return to Red state Reference Diagram 1 Note LED wire is unconnected Mode 2 Green LED ON...

Страница 15: ...COM Blue 6 EGND Brown 7 LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 Not Used 12 24VDC H N G 120 VAC Input H1 Harmony Series 12VDC DATA 1 DATA 0 RX RX Electronic Acce...

Страница 16: ...anel By Others Use NC for Fail Safe Operation Lock Relay NO Fail Secure Operation READER NEG Black 1 READER POS Red 2 DATA 1 White 3 DATA 0 Green 4 RX NO NC Orange 5 RX COM Blue 6 EGND Brown 7 LED Yel...

Страница 17: ...Lock body Power Supply By Others 12 24VDC H N G 120 VAC Input H1 Harmony Series Black Hot White Neutral Green Gnd READER NEG Black 1 READER POS Red 2 DATA 1 White 3 DATA 0 Green 4 RX NO NC Orange 5 RX...

Страница 18: ...EADER POS Red 2 DATA 1 White 3 DATA 0 Green 4 RX NO Orange 5 RX COM Blue 6 EGND Brown 7 LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 HES 2001M P1 P2 P3 P4 R1 R2 R3 R4...

Страница 19: ...ader is ON Red or Green depending on reader configuration See reader LED Configuration 3 Present proximity credential and verify LED and sounder activity 4 Verify valid card read at EAC panel 5 Verify...

Страница 20: ...construction institutional and industrial markets Copyright 2015 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express wri...