Copyright © 2015, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
05/15/15
Harmony Series H1 Mortise Lock
A7877F • 800-810-WIRE (9473) • www.sargentlock.com
18
Harmony H1 8200 UL 294 Application Diagram
UL 294 Requirements
• HID EDGE E400 or ES400
• POE Injector Altronix Netway1
• SARGENT 3540 / Securitron BPS-24-2
• HES 2001M MOV / Bridge (Optional)
• LED Wire Use as Required
12 Conductor
ElectroLynx Harness
From McKinney
QC12 Electric
Hinge From
McKinney
Harmony Series H1
P22 GND
P23 PWR
P23 DATA 1
P23 DATA 0
P106 REX (+)
P106 REX (-)
P105 DS COM
P105 DS NO
P106 DOOR MON (+)
P106 DOOR MON (-)
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
EGND- Brown, 7
LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
HES
2001M
P1
P2
P3
P4
R1
R2
R3
R4
H
F2
FA
F1
H
N
G
120 V
AC Input
Fir
e Alarm Contacts
24 VDC Positive Outputs
24 VDC Negative Outputs
To NC Fir
e Alarm Contacts
120 VAC
HID EDGE E400/
ES400
RJ45
PORT
ALTRONIX NETWAY1
OUT
IN
ALTRONIX
RJ45 PORTS
ALTRONIX
POWER INPUTS
NON-POLAR
CAT5e OR
GREATER
CABLE
IN used for
Networking/
Monitoring
Connection
Tape Purple/Black
Wires (Unused)
Red
Red/Green
Black
Black
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
*UL 294 is a United States based standard.
Use as Required
UL 294 Compliance
8
NOTE:
If your lock is configured with End of Line Resistors,
reference instruction sheet A8191 for the wiring of
RX & DPS outputs.