![Assa Abloy Harmony H1 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/assa-abloy/harmony-h1/harmony-h1_installation-instructions-manual_2988362019.webp)
05/15/15
Copyright © 2015, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
Harmony Series H1 Mortise Lock
A7877F • 800-810-WIRE (9473) • www.sargentlock.com 19
For 82280-82283 & 82270-82273 Function mortise locks with cylinders:
1. Insert key into cylinder and rotate: There should be no friction against
lock case, wire harness or any other obstructions.
2. The key will retract the latch: Key should rotate freely.
3. When the deadbolt is thrown: Ensure that the key retracts both the
deadbolt and the latch.
4. Inside lever: When used, ensure it retracts both the latch
and deadbolt (if provided).
5. Close door: Ensure latch and deadbolt fully extend
and do not bind.
Note: Once electrical wiring has been successfully
completed according to proper application, follow
the following steps:
1. Turn power ON.
2. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader LED
Configuration).
3. Present proximity credential and verify LED and
sounder activity.
4. Verify valid card read at EAC panel.
5. Verify system operation functions; i.e., when Prox credential
is presented to reader that the door unlocks.
Mechanical Operational Check
9
Electrical Operational Check
10
Feature
WT1
WT2
12 or 24VDC solenoid
lock voltage adjustable
X
X
Operates as Fail Safe or
Fail Secure
X
X
"Learn" mode allows
testing of specific cards
without programming at
the panel level
X
X
Card reader data inte-
grity is validated at test
unit
X
X
Works with SE LP10
X
X
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
X
Displays measured end-
of-line resistor values
(if applicable)
X
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product’s features and capabilities.
Wiegand Test Unit