background image

1) Regulatory Compliance

2) Warning

Changes or modifications to this unit not expressly approved by the party responsible 
for compliance could void the user’s authority to operate the equipment.

FCC

:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and 

can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Industry Canada:

This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. 

Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. 

L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter 

n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and 

operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with 

any other antenna or transmitter.

Cet équipement est conforme aux limites d’exposition aux radiations de la FCC définies pour un environnement non contrôlé. Cet équipement doit 

être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-localisé ou fonctionner en 

conjonction avec une autre antenne ou un autre émetteur.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for 

the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the 

equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal 

(ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres 

utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité 

nécessaire à l’établissement d’une communication satisfaisante.

To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:

• 

 Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, latches, and  

          mounting plates especially when mounting electronic components such as readers and controllers onto the door.

• 

Leave components (reader and controller) protected in their respective anti-static bags until ready for installation

• 

Do not touch pins, leads or solder connections on the circuit boards

This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm.  

For more information go to: 

www.P65warnings.ca.gov

.

Ce produit peut vous exposer au plomb qui, dans l’état de la Californie, est reconnu pour causer le cancer, des anomalies congénitales ou 

d’autres problèmes de reproduction.
Pour plus d’informations, visitez: 

www.P65warnings.ca.gov

.

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin makes 

no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire 

rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having 

Jurisdiction) to ensure compliance with all applicable codes and ratings.

!

3

EcoFlex

 Electrified Mortise Locks (NAC-)

with High-Security Monitoring Options             

Installation and Wiring Instructions

Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. 

All rights reserved. Reproduction in whole or in part without the express 

written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. 

is prohibited.

Содержание Corbin Russwin EcoFlex NAC Series

Страница 1: ...ment can cause premature wear and a lessening of security For Technical Assistance call Corbin Russwin at 1 800 810 WIRE 9473 Attention Installer FM405 05 20 EcoFlex Electrified Mortise Locks NAC with...

Страница 2: ...structions 15 8 Operational Check 16 2 EcoFlex Electrified Mortise Locks NAC with High Security Monitoring Options Installation and Wiring Instructions Copyright 2020 ASSA ABLOY Access and Egress Hard...

Страница 3: ...ner en conjonction avec une autre antenne ou un autre metteur Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved f...

Страница 4: ...ons of our industry leading Integrated Wired locks are now available in a mortise lock that can be used as a stand alone electrified lock or in conjunction with a wall reader Every NAC lock is shipped...

Страница 5: ...coFlex Electrified Mortise Locks NAC with High Security Monitoring Options Installation and Wiring Instructions Copyright 2020 ASSA ABLOY Access and Egress Hardware Group Inc All rights reserved Repro...

Страница 6: ...RH Open Outward RHRB 2 Prep door according to supplied door marker For door manufacturer templates visit www corbinrusswin com Inside Face of Door Outside Face of Door 6 EcoFlex Electrified Mortise Lo...

Страница 7: ...g 3 Note Push in latch until catch plate is no longer depressed Fig 4 GOOD BAD Step 5 Rotate lock front to match bevel of door as shown Fig 5 Figure 4 WARNING LOCK IN CAN OCCUR IF LATCH IS NOT PROPERL...

Страница 8: ...oor stop Install but do not tighten two 12 x 1 b combination screws through lock body Fig 5 Outside Face of Door 2 12 x 1 Fig 5 Do not tighten 8 EcoFlex Electrified Mortise Locks NAC with High Securit...

Страница 9: ...functions correctly latch deadbolt and key Fig 6b1 Position cylinder so that the logo is right side up Fig 6b Fig 6a1 9 EcoFlex Electrified Mortise Locks NAC with High Security Monitoring Options Ins...

Страница 10: ...tep 2 Step 3 Outside Face of Door Inside Face of Door Fig 11c Fig 11d 10 EcoFlex Electrified Mortise Locks NAC with High Security Monitoring Options Installation and Wiring Instructions Copyright 2020...

Страница 11: ...r turns for a good starting point After being fully tightened Make sure O S lever is fully inserted into adapter plate before aligning adjustment bolt 6 Installation Instructions Continued Fig 4a 11 E...

Страница 12: ...be used to help thread hub into lever Adapter Plate Hub 2 INSIDE OUTSIDE 12 EcoFlex Electrified Mortise Locks NAC with High Security Monitoring Options Installation and Wiring Instructions Copyright...

Страница 13: ...nued 13 EcoFlex Electrified Mortise Locks NAC with High Security Monitoring Options Installation and Wiring Instructions Copyright 2020 ASSA ABLOY Access and Egress Hardware Group Inc All rights reser...

Страница 14: ...4 5 6 7 8 12 24VDC Lock Input Door Position Request to Exit Empty Empty Black Red White Green Orange Blue NEG POS NC COM NO NC COM Description Connector Circuit Wire Color Connection 4 PIN MOLEX 1 2...

Страница 15: ...ect signaling by referencing instruction sheet FM406 Feature WT1 WT2 12 or 24VDC solenoid lock voltage adjustable X X Operates as Fail Safe or Fail Secure X X Learn mode allows testing of specific car...

Страница 16: ...and Edge are trademarks or registered trademarks of HID Global in the U S and or other countries All other trademarks service marks and product or service names are trademarks or registered trademarks...

Отзывы: