ED5000N  Series  Exit  Devices  For                                             

9700 TCPIP1 & PWI1 Series Trim

1) Warning

Table of Contents

1)   Warning  ......................................................................................................... 2
2)   General Description  ...................................................................................... 3
3)   Specifications / Features .............................................................................. 3
4)   Product Illustration ....................................................................................... 4
5)   Rim Exit Installation Instructions ................................................................. 5
6)   Mortise Exit Installation Instructions ........................................................... 9
7)   Install Outside Escutcheon  ........................................................................13
8)   PIP (PoE) Installation & Wiring .................................................................... 14 
9)   PWI (Wireless) Installation .......................................................................... 22
10) Operational Check ....................................................................................... 26

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, 

and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment 

does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try 

to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced technician for help
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus 

meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may 

not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est 

sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence 

reçue, y compris l’interférence qui peut causer l’opération peu désirée.

Warning: Changes or modifications to this unit not expressly approved by the party  
responsible for compliance could void the user’s authority to operate the equipment.

!

!

To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:

• Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges,  latches, and  

   mounting plates especially when mounting electronic components such as readers and controllers onto the door

• Leave components (reader and controller) protected in their respective anti-static bags until ready for installation

• Do not touch pins, leads or solder connections on the circuit boards

*Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin, Inc. 

makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an 

existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official 

(Authorities Having Jurisdiction) to ensure compliance with all applicable codes and ratings.

To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.

!

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard 

for Electrical Installations, local codes, and the Authorities Having Jurisdiction (AHJ).

This product is not intended for outside wiring per NFPA 70

Содержание Corbin Russwin Access 700 ED5000N Series

Страница 1: ...ignment can cause premature wear and a lessening of security For Technical Assistance call Corbin Russwin at 1 800 810 WIRE 9473 Copyright 2018 Corbin Russwin Inc an ASSA ABLOY Group company All right...

Страница 2: ...the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interfer...

Страница 3: ...4 Indoor Use CUL Listed CAN ULC S319 05 Equipment Class I WiFi IEEE 802 11 b g n Support for most advanced wireless encryption and authentication standards such as WEP WPA WPA2 and 802 1x Power Requir...

Страница 4: ...and Keypad 784585 FIN Outside Escutcheon Assemby Mag Swipe Keypad HID 125kHz Prox and 13 56 MHz Prox 784595 FIN Outside Escutcheon Assemby Mag Swipe HID 125kHz Prox and 13 56 MHz Prox 784F605 FIN Outs...

Страница 5: ...n and hand Left Hand Reverse LHR Outside Inside Right Hand Reverse RHR Outside of Door Inside of Door 2 Prep door according to supplied Door Marker FM410 For door manufacturer templates visit www corb...

Страница 6: ...p 5 b If required modify by cutting cylinder tailpiece Correct length is 1 16 to 3 16 2 to 5mm beyond cylinder housing cam c Assemble cylinder 1 Insert cylinder housing prongs into matching notches of...

Страница 7: ...m Exit Installation Instructions Continued Fig 4c 4 Install Rim Exit Device a Seat device against door being careful to align vertical trim tailpiece to engage with cross hole of device cam see Figure...

Страница 8: ...1 Series Trim 5 Rim Exit Installation Instructions Continued 5 Install Head Cover a Lay device wire harnesses across hole Fig 5a b Tuck wires into hole when installing cover so that wires are not pinc...

Страница 9: ...e of exit device function and hand Left Hand Reverse LHR Outside Inside Right Hand Reverse RHR Outside of Door Inside of Door 2 Prep door according to supplied Door Marker FM410 For door manufacturer...

Страница 10: ...e tailpiece is oriented vertically b Feed trim wire harness through wire harness hole Fig 3a c Mount trim assembly to door pulling slack wire towards device side of door Note Be careful not to pinch w...

Страница 11: ...700 TCPIP1 PWI1 Series Trim Tighten securely 4 Install Exit Device 6 Mortise Exit Installation Instructions Continued Fig 4a Fig 4b a Seat device against door being careful to align vertical trim tail...

Страница 12: ...eries Trim 5 Install Head Cover a Lay device wire harnesses across hole Fig 5a b Tuck wires into hole when installing cover so that wires are not pinched between head cover and door c Attach head cove...

Страница 13: ...ess If you are installing PIP PoE If you are installing PWI Wireless go to Page 22 Section 9 PWI Installation Instruction Reader Harness 1 Install optional Weatherseal Gasket For non fire rated door a...

Страница 14: ...es For 9700 TCPIP1 PWI1 Series Trim 8 PIP PoE Wiring and Installation Overview Corbin Russwin ED5000N PIP PoE Typical Application LMT Lock Management Tool A PoE frame harness assembly B PoE data hinge...

Страница 15: ...for Earth Ground in 15 Frame Harness Cable drain wire concealed in shrink tubing Patch Panel Cable CAT 5e or higher 24 AWG RJ45 F Jack Approved Software Certified Integrator CI supplies and terminate...

Страница 16: ...able drain wire concealed in shrink tubing Frame Harness Installation Hinge side of PoE Frame harness 4 pin M 6 pin M Frame PoE Hinge PoE Data Hinge Hinge side harness connectors 4 pin female molex co...

Страница 17: ...e Molex connector with ground wire Lock side harness connectors Ring terminal Male RJ45 connector crimped after cable is fed through door Notes Connectors go on only one way They cannot be plugged to...

Страница 18: ...tral opening of mounting plate Fig 8a b Lockbody cable feeds from bottom Fig 8a b c Ensure ground lug is positioned as shown Fig 8a b d Insert other three 8 32 x 1 7 8 flat head machine screws and tig...

Страница 19: ...nnector contacts Secure Mounting Plate B Secure the 24 pin card reader connector Fig 9A C Crimp RJ45 to Cat 5e cable from hinge Fig 9B For more detail refer to section 5 Installation Wiring A Frame Ha...

Страница 20: ...on mounting plate Fig 10a b Ensure proper alignment of board to board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate CAUTIO...

Страница 21: ...Exit Devices For 9700 TCPIP1 PWI1 Series Trim End of PIP PoE Installation Instructions Proceed to Section 10 Operational Check Security Allen Screw 4 Inside Cover Installation a Install cover by hook...

Страница 22: ...m Mounting Plate a Feed reader cable through central opening of mounting plate Fig 12a b b Lockbody cable feeds from bottom Fig 12a b c Ensure ground lug is positioned upright Fig 12a b d Insert other...

Страница 23: ...der connector CAUTION Do not touch or allow debris to enter connector contacts NOTE Optional 2 pin external 9 24VDC power connector PWI1 Wireless only Wire Positioning Please follow these steps prior...

Страница 24: ...top tabs of controller into slots on mounting plate Fig 14 b Ensure proper alignment of board to board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely in...

Страница 25: ...are installed there is a slight delay then an audible beep will sound and the lock motor will cycle d Secure cover with 2 security screws utilizing T 20 security torx driver Fig 15b For battery replac...

Страница 26: ...should extend and retract the deadbolt For units without a keypad add card using LCT software and test For units with a keypad add pin and card using LCT software and test 2 LED signaling After using...

Страница 27: ......

Страница 28: ...ries Exit Devices 28 Copyright 2018 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is...

Отзывы: