9700 TCPIP1 & PWI1 Series Trim
8) PIP (PoE) Wiring & Installation (Continued)
PoE
Harness
(cat5e)
Order of installation may vary. Refer to appropriate sections for instructions.
Hinge-side harness connectors:
• 4-pin male Molex connector
• 6-pin male Molex connector with ground wire
Lock-side harness connectors:
• Ring terminal
• Male RJ45 connector
(crimped after cable is fed through door)
Notes:
• Connectors go on only one way. They cannot be plugged to incorrect position.
• Do not force and do not offset connectors.
• Be sure they are completely seated (flush).
Order of installation may vary. Refer to appropriate sections for instructions.
1. Prop door open.
2. Using the ring terminal, carefully route the assembly through the door
channel toward lock.
PoE Door Harness
PoE Lock
4-pin F
4-pin M
4-pin F
6-pin F
6-pin F
6-pin M
Cable
: CAT 5e,
26 AWG stranded,
100ohm
Drain Wire
PoE Lock
D
C
RJ45-M
PoE Hinge
PoE Door Harness