CL33600 Series Cylindrical Lock
3
Copyright © 2017 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
The Corbin Russwin Access 600 TCRNE1 Series cylindrical lock is designed to interface with existing Wiegand
Electrical Access Control (EAC) panels. The reader requires 12VDC for power and is available with 125kHz HID
proximity technology. The Access 600 technology is designed around Corbin Russwin’s Grade 1 hardware. The
cylindrical lock comes with complete inside REX (request to exit) monitoring and is available in 12VDC or 24VDC
(Requires External DPS – Door Position Switch). Weather seal gaskets are also included for outdoor applications.
The Access 600 reader provides visual (LED) and audible indication of lock state (locked/unlocked).
• Latch:
Stainless steel, ½” (13mm) throw
Optional: 3/4” (19mm) throw deadlocking fire latch
for pairs of doors
• Deadlocking latch prevents manipulation when door closed
• Door thickness: 1-3/4” (44mm) to 2” (50mm) standard
2” (50mm) to 2-1/4” (57mm) optional
• Outside lever controlled by reader or key retracts latch
• Inside lever produces REX (request to exit) signal
• Fail safe or fail secure operation (must specify)
• UL fire listed
• Wire from EAC panel to door must be shielded with a drain.
Drain terminated at EAC panel controller
• Complete monitoring of door (external DPS supplied)
• Wires directly to EAC panels
• Accepts all HID 125kHz bit formats
• QC12 Hinge with ElectroLynx plug and play
2) General Description
3) Features
DPS (Door
Position Switch)
McKinney
Electronic
Transfer
Hinge
Wiegand Access
Control System
CL33600
Series Lock
Patent Pending
4) Regulatory Specifications
• UL 294 Access Control Performance Ratings:
Destructive Attack
Level I
Line Security
Level I
Endurance
Level IV
Standby Power
Level I
• ANSI/BHMA A156.25 Listed Grade 1 Compliant
• UL and CUL listed for use on Fire Doors
• This product meets the requirements of CAN/ULC-S319-05 Equipment Class I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.
12VDC System
• Reader Draw = 125mA (maximum)
• 12VDC Solenoid Draw =250mA (normal state)
• Total System Draw = 375mA
24VDC System
• Reader Draw = 125mA (maximum)
• 24VDC Solenoid Draw = 150mA (normal state)
• Total System Draw = 275mA