Mechanical Installation
Fixed Sidelite Active Leaf Installation Procedure - Unequal Panel ONLY
1. Position the door panel in the open
position. Rotate the bottom roller foot
guide perpendicular to the door.
2. Place the door under the cover, being
careful not to damage the cover, and
insert the roller foot guide into the cut-
out in the bottom corner of the sidelite.
See Fig. 10.
3. Then tilt and lift the wheel brackets on
top of the door onto the track inside the
header.
4. Install the anti-risers by sliding the
door past the anti-riser block and lin-
ing up the carrier and block. Insert
anti-riser bolt and secure. See Fig. 11,
Pg. 25.
5. Adjust the vertical adjustment screw
on the PSA arm to lift the lead edge of
the door and ball catch into alignment
with the ball catch receiver. See Fig. 12,
Pg. 25.
Note:
if the glass has not been previously
installed, you will need to recheck align-
ment once the glass is in place and read-
just as necessary.
6. Loosen wheel brackets and adjust door
to proper height using the adjustment
screw on the wheel brackets, taking
into account the floor conditions for
the full travel of the doors. Tighten
wheel brackets.
Fig. 10