Issue 7-23-2007
Besam ICU/CCU - Equal or Unequal Panel
1
© Copyright 2007 Besam Entrance Solutions. May not be reprinted or reproduced without permission.
Mechanical Installation
Opening/Closing and Locking of Cover
The cover has to be unlocked in order to gain access into header. The locks
are located at each end of the cover, next to the jambs.
1. To unlock, insert the short leg of a 1/4" Allen wrench between the header
and cover, just above the weather-stripping. Rotate the wrench 90
o
toward the
cover. Feel for lip on the lock and slide about a 1/2" away from the jamb.
Gently pull up on the cover to ensure the lock has completely disengaged
from the jamb. Repeat for the other side.
2. To lock, reverse the order of Step 1.
The cover is designed to be self-supporting in the open position. To open,
stand at the center of the cover, rotate the cover 90
o
, and then push inward
toward the header. This will engage the cover into the header, preventing it
from closing. To close, pull the cover away from the header until it disen-
gages and swings freely.