Issue 7-23-2007
13
Besam ICU/CCU - Equal or Unequal Panel
© Copyright 2007 Besam Entrance Solutions. May not be reprinted or reproduced without permission.
Installation Requirements
Fastening Requirements
Base door / wall material
Minimum anchor / bolt requirement*
Steel
3/16" (5 mm)*
Aluminium
1/4" (6 mm)*
Reinforced concrete
min. 2" (50 mm) from the underside
Wood
2" (50 mm)
Brick wall
Expansion-shell bolt, min. (1/4" x 3 1/2"),
min. 2" (50 mm) from the underside
* Besam minimum recommended requirements. Building Codes may give dif-
ferent specifications.
* Thinner wall profiles must be reinforced with rivnuts.
Tools required
Carpenter's level
Tape rule
Straight edge
Power drill and set of drill bits, Unibit, Hammer drill
Metric hex key set 6, 5, 4 mm and 2.5 mm
Screw driver Torx T10, T20
Flat blade screw driver (small/medium/large)
Screw driver
Chalk line
#2 Phillips screw driver
Center punch
String
Plumb bob
Silicone sealant
Pencil
10mm Nut Driver and wrench