Warranty exclusions / Exclusions de la GarantÍa

ENG

ENG

ES

WARRANTY WILL BE VOIDED IF ANY OF THE FOLLOWING CONDITIONS ARE FOUND:

1. Sealed motor housing is opened.
2.  Pump is connected to voltage other than indicated on name plate ( or to voltage which is more than 10% 

below rated voltage of pump.

3. Overflow switch cable is cut off to a length of less than 6 inches.
4. Pump is allowed to operate dry.
5. Pump is used to circulate anything other than condensate water at a maximum temperature of 104º F. 
6. Product abuse by installer or customer. 
7. Overflow switch circuit is not connected as mandated on page 9, Item 10. 
8. Internal pump components have been exposed to unapproved coil cleaners or other chemical substances. 
 

LA GARANTÍA SERÁ ANULADA SI SE ENCUENTRA CUALQUIERA DE LAS SIGUIENTES CONDICIONES:

1. Se abre la caja hermética del motor.
2.  Se conecta la bomba a una tensión diferente de la que está indicada en la placa de identificación (o a una 

tensión que es de más de 10% por debajo de la tensión nominal de la bomba).

3.  Se corta el cable del interruptor de auto-evacuación de desbordamiento a una longitud de menos de 6 

pulgadas.

4. Se deja funcionar la bomba en seco.5. Pump is allowed to operate dry.
5.  Se utiliza la bomba para hacer circular cualquier fluido que no sea agua condensada a una temperatura 

máxima de 104ºF.

6. Abuso del producto por el instalador o cliente.
7. El circuito del interruptor de auto-evacuación de desbordamiento no está conectado de la manera exigida en 
la página 9, Punto 10. 
8.  Los componentes internos de la bomba han sido expuestos a limpiadores de serpentines no aprobados u otras 

sustancias químicas. 

IN ORDER TO FULLY UNDERSTAND THE OPERATION OF THESE PUMPS, IT IS NECESSARY TO 

UNDERSTAND SOME OF THEIR BASIC PRINCIPLES OF OPERATION:

All minisplit piston pumps share some common characteristics:

1.  They are self priming.
2.  They are water cooled.
3.  They are water lubricated.

This means that when they are activated, they will self prime, however during this initial period they will draw in air 
and while this is happening they will be running both hot and dry.

Because of this, 

they will emit a clicking noise which is entirely normal during the initial start up phase 

only,

 (usually around 10 seconds or less) and this will stop when all of the air in the pump intake has been purged 

and the pump becomes cooled and lubricated by the water flowing through it.

IF THE CLICKING NOISE IS HEARD WHILE THE PUMP IS OPERATING AFTER THE INITIAL START UP HAS BEEN 
COMPLETED, THIS IS AN ABNORMAL SITUATION WHICH INDICATES THAT THERE IS A PROBLEM AND THE 
PUMP IS RUNNING WITHOUT COOLING OR LUBRICATION AND IS OVERHEATING.

This usually occurs in a split pump because the intake hose (¼” clear vinyl hose between the reservoir and the pump) 
has emptied itself due to a siphoning effect created by atmospheric pressure.

THEREFORE IT IS VITAL THAT THE INTAKE HOSE IS KEPT FULL OF WATER AT ALL TIMES SO THAT NO AIR IS PRESENT 
FOR THE PUMP TO DRAW IN WHEN IT STARTS OPERATING. 

AS LONG AS THE INTAKE HOSE REMAINS FULL OF WATER, EVERY TIME THE PUMP STARTS UP IT IS IMMEDIATELY 
COOLED AND LUBRICATED BY THE WATER FLOWING THROUGH IT AND WILL OPERATE AS DESIGNED, WITH 
MINIMAL NOISE.

EACH PUMP IS FITTED WITH A THERMAL OVERLOAD PROTECTOR WHICH WILL DEACTIVATE IT IN CASE OF 
OVERHEATING, HOWEVER, ONCE IT COOLS DOWN IT WILL BEGIN TO OPERATE AGAIN, AND IF THE PUMP IS 
ALLOWED TO CONTINUE TO OPERATE FOR A SUSTAINED PERIOD OF TIME IN THIS CONDITION, IT WILL FAIL.

In some applications, the vertical distance between the reservoir and the pump can be up to 6 feet and the longer 
this distance, the longer the pump will have to operate hot and dry before it evacuates the air from the intake tube 
and, therefore, the longer time it will have in which to damage itself.

If the end of the discharge hose is lower than the level of the drain pain in the evaporator, the weight of the water in 
the discharge hose plus atmospheric pressure on the water in the drain pan will cause the water to continue flowing, 

EVEN AFTER THE PUMP HAS SWITCHED ITSELF OFF,

 until all the water in the system has evacuated itself.

IMPORTANT NOTES: 

 

USING DISCHARGE HOSE OTHER THAN THE SIZE SPECIFIED (¼” ID)  MAY RESULT IN REDUCED 
PERFORMANCE.

CORRECT INSTALLATION OF SUPPLIED ANTI SIPHON DEVICE WILL ELIMINATE SIPHONING AND REPLACE AIR 
BREAK AS SHOWN ON PAGE 4

Guidelines for  

Installation of Discharge Hosing

14

15

Содержание mini aqua pump

Страница 1: ...ht charges for the replacement product Defective product returned to the factory prepaid will be repaired or replaced free of charge Replacement product will to the extent such product is then available in the manufacturer s inventory be of a similar type of color and kind Manufacturer retains the right to substitute product if the replacement product does not conform in terms of color type and sp...

Страница 2: ...ISE LEVEL IS PRESENT THE SOUND OF THEIR INTERMITTENT OPERATION MAY STILL BE PERCEIVED AS NOISY AND THE PUMP MAY HAVE TO BE SITED OUTSIDE THE SENSITIVE AREA ALWAYS CONFIRM ACCEPTABLE NOISE LEVEL BEFORE INSTALLING ANY CONDENSATE PUMP IN A BEDROOM OR OTHER NOISE SENSITIVE AREA CONSULT RECTORSEAL FOR FURTHER INFORMATION AND FOR DETAILS OF ALTERNATIVE PUMPING METHODS PH 713 263 8001 800 231 3345 FAX 71...

Страница 3: ...he Discharge Hose Installation Guide on page 16 17 Note for Silent models The ASD should be installed at the end of the silicone tubing connected to the mini pump and be used as the transition to I D vinyl tubing PREVENCIÓN DEL SIFONAJE Si el extremo de la manguera de descarga está por encima del nivel de la cubeta de drenaje en el evaporador no puede haber sifonaje y las medidas de antisifonaje n...

Страница 4: ...tube is above maximum water level in drain tray NOTE BREATHER TUBE IS CRITICAL TO CORRECT OPERATION OF PUMP AND MUST REMAIN IN PLACE AND FREE OF RESTRICTIONS AT ALL TIMES Encaje el tubo respirador en la tapa del depósito segurese que el tope del tubo este sobre el máximo nivel de agua en la bandeja de desagüe NOTA EL RESPIRADERO ES CRÍTICO PARA EL FUNCIONAMIENTO CORRECTO DE LA BOMBA Y DEBE PERMANE...

Страница 5: ... as per detailed wiring diagram from our website If no alarm is required isolate orange wire with a wirenut Some evaporators provide numbered terminals for connection of the gray and purple overflow alarm wires directly into the PCB refer to relevant factory approved diagrams for correct wiring instructions Most VRF systems e g City Multi ECO I VRF III and Multi V require constant communication be...

Страница 6: ... DE FÁBRICA PARA LAS CORRECTAS INSTRUCCIONES DE ALAMBRADO Y O CONEXIONADO THESE ARE GENERIC DIAGRAMS FOR REFERENCE PURPOSES ONLY AS WIRING PROTOCOLS VARY FROM ONE MINISPLIT MANUFACTURER TO ANOTHER FACTORY APPROVED WIRING DIAGRAMS FOR MOST MODELS OF ALL MAJOR MINISPLIT BRANDS CAN BE FOUND ON OUR WEBSITE AT www rectorseal com or call 1 800 231 3345 for onsite assistance ÉSTOS SON DIAGRAMAS GENÉRICOS...

Страница 7: ... from resting on the reservoir bottom This may occur if pump has been operated for some time without cleaning Clean with an anti bacterial cleansing solution NOTE The pump will only switch off when the float is actually resting on the bottom of reservoir 4 Does evaporator produce more condensate than pump can handle If so pump is too small and must be replaced with a different type Fault Vibration...

Страница 8: ...ry Because of this they will emit a clicking noise which is entirely normal during the initial start up phase only usually around 10 seconds or less and this will stop when all of the air in the pump intake has been purged and the pump becomes cooled and lubricated by the water flowing through it IF THE CLICKING NOISE IS HEARD WHILE THE PUMP IS OPERATING AFTER THE INITIAL START UP HAS BEEN COMPLET...

Страница 9: ... que toda el agua en el sistema haya sido evacuada por si sola NOTAS IMPORTANTES EL USO DE UNA MANGUERA DE DESCARGA DE TAMAÑO DIFERENTE AL TAMAÑO ESPECIFICADO DI PUEDE REDUCIR EL RENDIMIENTO LA INSTALACIÓN CORRECTA DEL DISPOSITIVO ANTISIFONAJE SUMINISTRADO ELIMINARÁ EL SIFONAJE Y REEMPLAZARÁ EL ESCAPE DE AIRE DE LA MANERA INDICADA EN LA PÁGINA 4 Gua para la Instalación de la Manguera de Descarga E...

Страница 10: ...rcionar el máximo nivel de protección contra el desbordamiento así como para garantizar que la instalación cumple con el código Aunque puede que este código aún no haya sido aplicado en todas las áreas ES MUY RECOMENDABLE QUE SE INSTALE OTRO INTERRUPTOR DE AUTO EVACUACIÓN DE DESBORDAMIENTO EN TODOS LOS EVAPORADORES MINISPLIT INCLUYENDO AQUELLOS QUE TIENEN BOMBAS MONTADAS EN LA FÁBRICA O BOMBAS DE ...

Страница 11: ...ito Tubo Respirador La Bandeja de Desagüe El Depósito Tubo Respirador 1 La bandeja de desagüe se llena con agua la cual fluye hacia el depósito La manguera de entrada entre el depósito y la bomba está vacía y llena con aire 2 El nivel de agua levanta el flotador activando la bomba la cual se auto purga por la succión de agua del depósito Durante este período la bomba está operando caliente y seca ...

Страница 12: ...rga la presión atmosférica esta igualada en ambos extremos de la manguera del sistema por eso el efecto sifón no podrá presentarse y LA MANGUERA DE ENTRADA PERMANECE LLENA CON AGUA 4 La bandeja de desagüe otra vez se llena con agua la cual fluye al depósito y activa la bomba LA MANGUERA DE ENTRADA YA ESTA LLENA CON AGUA de allí que no sea succionado aire y la bomba es inmediatamente enfriada y lub...

Страница 13: ...Mini condensate pumps Novent Locking refrigerant caps Big Foot AC rooftop mounting system RectorSeal AC equipment mounting Slimduct Condensate drain hose RectorSeal 2601 Spenwick Drive Houston TX 77055 ph 713 263 8001 800 231 3345 fax 713 263 7577 800 441 0051 www rectorseal com Like Us on Facebook Scan for more info BRLDK 4 2013 961890 ...

Отзывы: