![ASO ISK 71?24 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/aso/isk-71-24/isk-71-24_operating-manual_2984506016.webp)
16
English
ISK 71‑24
Transmit Opening
Stationary Opening
Transmit
Stationary
Power
ISK 71‑24
3
3 11
10 1 2
2
2
2
2
4
3
1
Gate opens
Gate closes
SCE
OPEN
movement
SCE
OPEN
movement
SCE
OPEN
movement
SCE
CLOSE
movement
SCE
CLOSE
movement
SCE
CLOSE
movement
Stationary Op.
Transmit
Stationary Cl.
Serial No.: 0 9 2 0 0 7 0 0 0 0 0
ISK 71‑94 V5.1
8 7
6 5 4
9
10 11 1 2
3
Power
Transmit Opening
Stationary Opening
Transmit Closing
Stationary Closing
ISK 71-24
Power
Transmit Opening
Stationary Opening
Transmit Closing
Stationary Closing
ISK 71-94
ISK 71-24 ISK 71-94
6. System components fitted to the gate
1 control device ISK 71‑24 (ISK 71‑94)
2 Stationary coil core
3 Travelling coil core
4 Steel cable acting as transmission medium
Example of use
The actual arrangement of the individual
components depends on the design of the
gate in question and the conditions at the
installation site.
7. Device overview
7.1 Signal indicators
LED
Power
green
Supply voltage
LED
Transmit Opening
red
Fault, opening movement ‑ travelling edge(s)
LED
Stationary Opening
red
Fault, opening movement stationary edge(s)
LED
Transmit Closing
red
Fault, closing movement ‑ travelling edge(s)
LED
Stationary Closing
red
Fault, closing movement ‑ stationary edge(s)
7.2 Connection terminals
ISK 71-24 + ISK 71-94 Inductive Safety Relay
ISK 71-94
Transmit
Stationary Op.
Stationary Cl.
Pin 4, 5
Pin 6, 7
Pin 8, 9
ISK 71-24
Pin 1, 2
stationary coil core
Pin 3, 11
SCE ‑ leading pillar opening
Pin 3, 10
SCE ‑ leading pillar closing
Pin 4, 5
relay output for controller ‑ stop opening
Pin 6, 7
relay output for controller ‑ stop closing
Pin 8, 9
supply voltage 24 V
Bottom