![ASM Polytouch HYDRASYNTH EXPLORER Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/asm/polytouch-hydrasynth-explorer/polytouch-hydrasynth-explorer_owners-manual_2984444073.webp)
73
keys: page 6
control parameter
range
Description
1
Aftertouch Delay
0-400 ms
(see description below)
2
Aftertouch Fade
0-400 ms
(see description below)
3
Aftertouch Offset
- 4 to + 4
(see description below)
4
Aftertouch Release
0-400 ms
(see description below)
aftertouch settings
• Aftertouch Delay: the time that transpires
between note on and the onset of aftertouch.
• Aftertouch fade: the time it takes to ramp
aftertouch to its current value from 0.
• Aftertouch curve: determines the amount of
force required to reach maximum aftertouch
values.
• Aftertouch Offset: reduces the dynamic range
of the aftertouch. Positive values set a higher
minimum point, so it takes more pressure to
start the aftertouch. Negative values set a
lower maximum point, so it takes less pressure
to reach the maximum aftertouch value.
• Aftertouch release: more like a compressor
than an envelope, this applies to all upwards
movements. This can help avoid unwanted
modulation “wobble” while pressure is applied,
and can sustain even after note off.
MiDi: page 7
control parameter
range
Description
1
Clock Sync
Internal, USB, MIDI In,
Auto
Clock source for Arp, LFOs, Envelopes, Delay
FX (see below)
2
Local
On, Off
Disconnect keyboard from internal engine
3
MIDI TX
1-16
Set MIDI transmission channel
4
MIDI RX
Omni, 1-16
Set MIDI receive channel
clock Sync
• inT run: selects Hydrasynth Explorer as the
master tempo clock. Sync signals are sent to
MIDI, USB, and the CV Clock output.
• uSB: selects the DAW as the clock master.
Sync signals are sent to MIDI and the CV Clock
output. Tempo cannot be changed from the
Hydrasynth Explorer.
• MiDi in: slaves the Hydrasynth Explorer to
incoming MIDI clock data. Sync signals are sent
to USB and the CV Clock output. Tempo cannot
be changed from the Hydrasynth Explorer.
• auTO: Hydrasynth Explorer sets the clock
source automatically to the first source that
arrives. If the clock signal is interrupted,
another is selected. Order of priority: USB >
MIDI > Internal.
local
When working with a DAW, setting Local to Off
can prevent a MIDI loop. Most DAWs have the
ability to prevent this also.
Содержание Polytouch HYDRASYNTH EXPLORER
Страница 2: ...OCTAVE MAX MIN ...