Drain Line Replacement
332763A
29
Drain Line Replacement
This procedure should be used whenever you replace
the manifold and reinstall an existing drain line or install
a new drain line using the Drain Line Kit.
Removal
To remove the drain line (40) from the manifold (15):
1.
Cut drain line (40) from barbed fitting (20).
2.
Unscrew barbed fitting from filter manifold (15).
NOTE:
To reuse existing barbed fitting (20) and drain
line (40), cut and remove remaining drain line material
from end of barbed fitting.
Installation
1.
Screw barbed fitting (20) into filter manifold (15).
2.
Push drain line (40) onto barbed fitting.
NOTE:
To make drain line more pliable and easier to
install over barbed fitting, heat end of drain line (40) with
a hair dryer or place end in hot water a few seconds.
20
40
ti9156a
15