General Repair Information
12
332763A
General Repair Information
•
Keep all screws, nuts, washers, gaskets, and elec-
trical fittings removed during repair procedures.
These parts usually are not provided with replace-
ment kits.
•
Test repairs after problems are corrected.
•
If sprayer does not operate properly, review repair
procedure to verify you did it correctly. See
Trou-
bleshooting
, page 13.
•
Overspray may build up in the air passages.
Remove any overspray and residue from air pas-
sages and openings in the enclosures whenever
you service sprayer.
•
Do not operate the sprayer without the motor shroud
in place. Replace if damaged. Motor shroud directs
cooling air around motor to prevent overheating and
insulate the control board from accidental electric
shock.
Flammable materials spilled on hot, bare, motor
could cause fire or explosion. To reduce risk of burns,
fire or explosion, do not operate sprayer with cover
removed.
NOTICE
Do not operate the sprayer without the motor shroud in
place. Replace if damaged. Motor shroud directs cool-
ing air around motor to prevent overheating. Operating
the sprayer without the motor shroud in place will result
in damage to the sprayer.
To reduce risk of serious injury, including electric
shock:
•
Do not touch moving or electric parts with fingers
or tools while testing repair.
•
Unplug sprayer when power is not required for
testing.
•
Install all covers, gaskets, screws and washers
before you operate sprayer.
NOTICE
•
Do not run sprayer dry for more than 30 seconds.
Doing so could damage pump packings.
•
Protect the internal drive parts of this sprayer from
water. Openings in the cover allow for air cooling of
the mechanical parts and electronics inside. If
water gets in these openings, the sprayer could
malfunction or be permanently damaged.
•
Prevent pump corrosion and damage from freez-
ing. Never leave water or water-base paint in
sprayer when its not in use in cold weather. Freez-
ing fluids can seriously damage sprayer. Store
sprayer with Pump Armor to protect sprayer during
storage.