VIPEDIA-12 – Installation Guide
U-0641-0344.doc – Issue: 06 complete, approved
Page 28 of 44
3.2.1.5
BOA01 - Contact Outputs (1 to 12) Connections
Field Connection
Screw-in Terminal
①
Connection to VIPEDIA-12
(via CAT5 patch lead)
Description Signal
Pin
+V supply input (18 – 40 V) / 500 mA
24 V
1
+V supply input (18 – 40 V) / 500 mA
24 V
2
From
external
power supply
0 V supply
0 V
3
Not applicable
(Connected to screw-in terminal
③
via the PCB.)
VIPEDIA-12’s
RJ45
Screw-in Terminal
②
BOA01’s
RJ45
④
②
Description Signal
Pin
Pin
Pin
Open-collector output 1 [7]
Contact 1 [7]
1
1
1
Open-collector output 2 [8]
Contact 2 [8]
2
2
2
Open-collector output 3 [9]
Contact 3 [9]
3
3
3
Open-collector output 4 [10]
Contact 4 [10]
4 6
6
Open-collector output 5 [11]
Contact 5 [11]
5 4
4
Open-collector output 6 [12]
Contact 6 [12]
6 5
5
+ve supply (as 18V-40 V power supply
input) for open-collector outputs
+Supply 7
7
7
+ve supply (as 18V-40 V power supply
input) for open-collector outputs
+Supply 8
8
8
Screw-in Terminal
③
Description Signal
Pin
Cable screen
SCREEN
1
DC supply output (18 – 40 V)
2
Cable screen
SCREEN
3
DC supply output (0 V)
0V
4
Cable screen
SCREEN
5
DC supply output (18 – 40 V)
6
Cable screen
SCREEN
7
To/From
external
device
DC supply output (0 V)
0V
8
Not applicable
1) An external DC power supply (18 – 40 V) must be connected to screw-in terminal
①
if the open-collector
outputs are to be powered from the screw-in terminal block
③
.
2) Open-collector output:
•
Numbers without brackets refer to CONTACTS OUT 1-6 connector
•