VIPEDIA-12 – Installation Guide
U-0641-0344.doc – Issue: 06 complete, approved
Page 15 of 44
①
18V-40V: Dual DC Power Supply
- +
IN
18-40V
2A
18-40V
2A
2
1
18V-40V: 2-way pluggable Wago cage clamp terminal (male)
Signal Description
+
+V supply (18 V to 40 V DC)
–
0 V supply
②
CONTACTS OUT 1-6 and 7-12: Contact Outputs 1 to 12
1
2
3
4
5
6
7
8
CONTACTS OUT
1-6
CONTACT OUTS 1-6: Standard RJ45 jack
Pin
CAT5 Cable (EIA 568-B)
Signal
Description
1 white/orange
Contact
1
Open-collector output 1
2 orange
Contact
2
Open-collector output 2
3 white/green
Contact
3
Open-collector output 3
4 blue
Contact
5
Open-collector output 5
5
white/blue Contact
6
Open-collector output 6
6 green
Contact
4
Open-collector output 4
7 white/brown
+Supply
+ve supply (as 18V-40V power supply
input) for open-collector outputs
8 brown
+Supply
+ve supply (as 18V-40V power supply
input) for open-collector outputs
1
2
3
4
5
6
7
8
7-12
CONTACTS OUT
CONTACT OUTS 7-12: Standard RJ45 jack
Pin CAT5 Cable (EIA 568-B)
Signal
Description
1 white/orange
Contact
7
Open-collector output 7
2 orange
Contact
8
Open-collector output 8
3 white/green
Contact
9
Open-collector output 9
4 blue
Contact
11 Open-collector output 11
5 white/blue
Contact
12 Open-collector output 12
6 green
Contact
10 Open-collector output 10
7 white/brown
+Supply
+ve supply (as 18V-40V power supply
input) for open-collector outputs
8 brown
+Supply
+ve supply (as 18V-40V power supply
input) for open-collector outputs