DANS01 – Installation Guide
Issue: 02 complete, approved
Page 7 of 12
7.
Ensure that all unused cable entry holes are fitted with blanking plugs.
!
!
Blanking plugs must be tightly fitted to preserve the unit's IP rating.
Spare blanking plugs can be ordered from ASL quoting 208112.
8.
Secure the back box; see fixing hole positions in
The DANS01 should be directed towards likely sources of ambient noise e.g. areas where people
congregate.
It should not be placed to localised sources of noise that would be unrepresentative of the area of
coverage.
Figure 4
Fixing hole centres (rear view)
160 mm
100 m
m
F
IXING HOLE
CE
NT
R
E
S
66 m
m
FIXING HOLE CENTRES
146 mm
60 mm
50 m
m
BACK BOX (REAR VIEW)
4 x blanking plugs shown as
example only.
9.
Fit gland or conduit.
10.
Ensure all swarf is removed from the enclosure.
11.
Seal all entry points.
!
!
Ensure all entry points are adequately sealed to preserve the unit’s IP rating.