DANS01 – Installation Guide
Issue: 02 complete, approved
Page 6 of 12
5.
Choose the required cable entry point or points, and remove the M20 blanking plug(s) at the chosen
position(s); see
6.
If rear entry is preferred, the installer may drill holes in the rear of the back box as described below.
a.
Remove the terminal plate by unscrewing the four corner fixings shown in
Figure 2
DANS01 terminal plate
4 x M3.5x6
POZI TAPTITE SCREWS
TERMINAL PLATE
b.
Drill a hole or holes in the back box for the cable gland or conduit entry. These should be in the
positions shown in
Figure 3
Rear cable entry drilling centres
160 mm
40 mm
80 mm
DRILLING CENTRES
100 m
m
60 mm
50 m
m
D
R
ILL
ING CE
NT
R
E
S
BACK BOX (REAR VIEW)
4 x blanking plugs shown as
example only.
c.
Deburr the newly drilled holes.
d.
Re-fit the terminal plate; see