-13-
© 2021 United States Stove Company
ROOM AIR FAN
When starting your stove the Room Air Fan will not
come on until the stove’s heat exchanger warms up.
This usually takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers
will run until the stove cools. This will take 30 minutes
or longer depending on the heat remaining in the
appliance. After the stove components stop running
all lights on the display will go out and the two digit
display will begin flashing “E3”
REFUELLING
CAUTION:
• THE HOPPER AND STOVE TOP WILL BE HOT
DURING OPERATION; THEREFORE, YOU
SHOULD ALWAYS USE SOME TYPE OF HAND
PROTECTION WHEN REFUELING YOUR STOVE.
• DO NOT TOUCH THE HOT SURFACES OF THE
STOVE. EDUCATE ALL CHILDREN ON THE
DANGERS OF A HIGH-TEMPERATURE STOVE.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS THE
STOVE.
• NEVER PLACE YOUR HAND NEAR THE AUGER
WHILE THE STOVE IS IN OPERATION.
• WE RECOMMEND YOU NOT LET THE HOPPER
DROP BELOW 1/4 FULL.
WARNING:
• KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFILLING.
• DO NOT OVERFILL HOPPER.
TAMPER WARNING
This wood heater has a manufacturer-set minimum
low burn rate that must not be altered. It is against
federal regulations to alter this setting or otherwise
operate this wood heater in a manner inconsistent
with operating instructions in this manual.
SHUTDOWN PROCEDURE
WARNING:
NEVER SHUT DOWN THIS UNIT BY UNPLUGGING
IT FROM THE POWER SOURCE.
Turning your stove off is a matter of pressing the
“POWER” button on the display board. The green
light will turn back to red when the “POWER” button
is pushed. The auger motor will stop, and the blowers
will continue to operate until the internal firebox
temperatures have fallen to a preset level.
1. Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset
thermodisc. This safety switch has two functions.
A. To recognize an overheat situation in the stove
and shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the
high-temperature thermodisc will automatically
shut down the auger, preventing the stove from
overheating.
NOTE: On some units, once tripped, like a circuit
breaker, the reset button will have to be pushed
before restarting your stove. On other units the
thermodisc has no reset button and will reset
itself once the stove has cooled. The manufacturer
recommends that you call customer service if this
occurs as this may indicate a more serious problem.
A service call may be required.
2. If the combustion blower fails, an air pressure
switch will automatically shut down the auger.
NOTE: Opening the stove door for more than
30 seconds during operation will cause enough
pressure change to activate the air switch, shutting
the fuel feed off. The stove will shut down and show
“E2” on the two digit display. The stove has to fully
shut down before restarting.
OPTIMAL OPERATION
This pellet stove has been certified by the US EPA
to meet strict 2020 guidelines. To Insure this unit
produces the optimal minimal emissions, it is critical
to follow the following guidelines.To achieve a “high
burn” your stove should be set on setting 5 with the
damper fully open.To achieve a “medium burn” your
stove should be set on setting 1 with the damper fully
closed.To achieve a “low burn” your stove should be
set on setting 1 with the damper open.Settings 2,3 &
4 will give you a higher heat output above medium
and the damper should be open for these settings.
If the door is opened while the stove is in operation
it must be closed within 30 seconds or the stove will
shut down. If the stove shuts down push the “On/
Off” button to re-start your stove. The stove will have
to fully shut down and turn off before you will be able
to restart the stove
OPERATION INSTRUCTIONS