16
© 2022 United States Stove Company
c. Lift the left and right panel up and out of the
unit.
Left
Panel
Right
Panel
d.
Remove fly ash.
It is possible that creosote may accumulate in the
exhaust fan therefore, this must be brushed clean.
The exhaust fan can be found behind the left side
panel (facing the front of the heater), the circulation
fan can be found behind the right side panel. To
access the igniter, remove the air inlet tube and
cover (2 screws). The auger motor is located in the
center rear of the unit. Note: When cleaning, take
care not to damage the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac
is designed for ash removal. Some regular vacuum
cleaner (i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
WARNING:
FAILURE TO PROPERLY MAINTENANCE
THE CLEAN OUTS WILL RESULT IN POOR
PERFORMANCE OF THIS STOVE.