10
© 2022 United States Stove Company
4.
Locate the center of the exhaust pipe of your
unit. This point should then be extended to
the interior wall of your house. Once you have
located the center point, on the interior wall, cut
a 7” (175 mm) diameter hole through the wall.
5. The next step is to install the wall thimble, refer
to the instructions which come with the wall
thimble for this step.
6.
Install the appropriate length of exhaust vent
pipe into the wall thimble. See steps 11 and 12
when determining the correct length of exhaust
vent to use.
7.
Outside Fresh Air is Mandatory when installing
this pellet stove room heater in airtight homes and
mobile homes. Be sure that the outside air vent
has an approved cap on it to prevent rodents from
entering. Be sure to install in location that won’t
become blocked with snow, etc.
8. Connect the exhaust vent pipe to the exhaust
outlet of your pellet stove.
9. Secure all vent joint connections with 3 screws.
Seal the exhaust vent joint connections with
high temperature silicone sealant.
10.
Push the unit straight back to the interior
wall, being sure to maintain the minimum
clearances to combustibles 2” (51 mm) to the
back of the unit. Seal the annular space of the
wall thimble and around the vent pipe with
high temperature silicone sealant.
11. The exhaust vent pipe must extend at least 12”
(300 mm) out past the exterior wall. Seal the
annular space of the wall thimble and around
the vent pipe with high temperature silicone
sealant.
12. Install an approved horizontal termination cap or
if necessary install a 90° elbow and appropriate
length of vertical venting. An approved vertical
vent cap is recommended.
THROUGH THE WALL INSTALLATION
(RECOMMENDED INSTALLATION)
TYPICAL THROUGH THE
WALL INSTALLATION
Canadian installations must conform to CAN/
CSA-B365. To vent the unit through the wall,
connect the pipe adapter to the exhaust motor
adapter. If the exhaust adapter is at least 18” (457
mm) above ground level, a straight section of
pellet vent pipe can be used through the wall.
Your heater dealer should be able to provide you
with a kit that will handle most of this installation,
which will include a wall thimble that will allow
the proper clearance through a combustible
wall. Once outside the structure, a 3” (76 mm)
clearance should be maintained from the outside
wall and a clean out tee should be placed on the
pipe with a 90-degree turn away from the house.
At this point, a 3ft (0.91m) (minimum) section of
pipe should be added with a horizontal cap, which
would complete the installation. A support bracket
should be placed just below the termination cap
or one every 4ft (1.22m) to make the system more
stable. If you live in an area that has heavy snowfall,
it is recommended that the installation be taller
than 3ft (0.91m) to get above the snowdrift line.
This same installation can be used if your heater is
below ground level by simply adding the clean-out
INSTALLATION
Содержание AP5617-P
Страница 27: ... 2022 United States Stove Company 27 NOTES ...