OPERATING INSTRUCTIONS
Flame Height: Six flame height levels are available.
While the flame height icon is displayed, pressing
the up or down button once will increase or
decrease the flame height by 1 of 6 levels.
If the flame height is at Level 1 and the down button
is pressed, all burners will turn off.
If in IPI mode, the pilot will also extinguish.
If in CPI mode, the pilot will remain on. If in Smart
Thermostat, the flame height function is not available
for manual adjustment. In Smart Thermostat, the
flame height regulates automatically.
FLAME OFF
FLAME LEVEL 1
FLAME LEVEL 5
FLAME LEVEL MAXIMUM
Fan Speed Control: The fan speed can be adjusted
through 6 speeds and off. To activate this function,
press the Mode button until it displays the fan icon.
Use the up/down arrow button to turn on, off, or
adjust the fan speed. Once you set the desired fan
control, the system will remember your selected
fan speed until you manually change it.
IPI AND CPI MODES
Intermittent Pilot and Continuous (Standing) Pilot
Features - First lights a pilot then uses the pilot
to ignite the main burners. The pilot can be set in
the CPI (Continuous Pilot Ignition) mode to allow
the pilot to remain on indefinitely by setting the
remote control to CPI mode. If the remote control is
set to the IPI (Intermittent Pilot Ignition) mode, the
pilot will only light and remain on while the main
burners are operating.
IPI Mode: This mode turns the pilot off when not in
use and only lights the pilot automatically when a
call for heat is made by the remote control.
CPI Mode: If set to CPI mode, the pilot will ignite
and remain on at all times.
SETTING TO IPI OR CPI MODE
With the remote control off, press the MODE
button. You will see either “CPI” or “IPI” displayed on
the screen. Press the UP arrow button to set “CPI”
mode and press the down arrow button to set “IPI”
mode. Once set to the desired setting, press On/Off
button to activate.
Recommended: Keep in CPI mode. While not
mandatory, this will keep the chimney heated for
proper updraft during burner ignition, and it will
also eliminate excessive condensation of exhaust
vapors on the door glass. NOTE: The snowflake icon
will be visible on the display always when in CPI
mode.
Leaving it in CPI mode will keep the body warm
and eliminate cold drafts and heat loss to the cold
air that is trapped inside the firebox.