STOVE INSTALLATION
CHECK GAS TYPE
Use proper gas type for the unit you are installing.
If you have conflicting gas type, do not install unit.
WARNING:
A QUALIFIED INSTALLER OR SERVICE PERSON
MUST CONNECT APPLIANCE TO GAS SUPPLY.
FOLLOW ALL LOCAL CODES.
See dealer where you purchased the unit for proper
unit according to your gas type.
INSTALL GAS PIPING TO FIREPLACE
LOCATION
Installation items needed before installing stove
and burner system, make sure you have the items
listed below.
• External regulator
• Tee joint
• Test gauge connection*
• Pipe wrench
• Sediment trap (recommended)
• Equipment shutoff valve*
• Piping (check local codes)
• Sealant (resistant to propane/LP gas) (supplied by
installer)
•
Approved flexible gas line with gas connector (if
allowed by local codes — not provided)
*A CSA design-certified equipment shutoff valve
with 1/8” NPT tap is an acceptable alternative to
test gauge connection. Purchase the CSA design-
certified equipment shutoff valve from your dealer.
For propane/LP connections only, the installer must
supply an external regulator. The external regulator
will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11 and
13 inches of water. If you do not reduce incoming
gas pressure, burner system regulator damage
could occur. Install external regulator with the vent
pointing down as shown. Pointing the vent down
protects it from freezing rain or sleet.
External
Regulator
100 gal. (min)
Propane/LP
Supply Tank
Vent Pointing
Down
External Regulator with Vent Pointing Down
(Propane/LP Only)
FP1977
CAUTION:
USE ONLY NEW BLACK IRON OR STEEL PIPE.
INTERNALLY TINNED COPPER OR COPPER
TUBING CAN BE USED PER NATIONAL FUEL
CODE, SECTION 2.6.3, PROVIDING GAS MEETS
HYDROGEN SULFIDE LIMITS, AND WHERE
PERMITTED BY LOCAL CODES. GAS PIPING
SYSTEM MUST BE SIZED TO PROVIDE MINIMUM
INLET PRESSURE (LISTED ON DATA PLATE) AT
THE MAXIMUM FLOW RATE (BTU/HR). UNDUE
PRESSURE LOSS WILL OCCUR IF THE PIPE IS
TOO SMALL.
CAUTION:
FOR PROPANE/LP UNITS, NEVER CONNECT
STOVE DIRECTLY TO THE PROPANE/LP
SUPPLY. THIS BURNER SYSTEM REQUIRES
AN EXTERNAL REGULATOR (NOT SUPPLIED).
INSTALL THE EXTERNAL REGULATOR
BETWEEN THE BURNER SYSTEM AND
PROPANE/LP SUPPLY.
WARNING:
EXTERNAL REGULATORS MAY BE NECESSARY
FOR NATURAL GAS. ONE - OR TWO - POUND
PER SQUARE INCH (PSI) SYSTEMS WILL
DAMAGE THIS APPLIANCE AND MAY CAUSE
FIRE HAZARD.