VENTING INSTALLATION
Restrictor Adjustment Guidelines
Flame
Appearance
Draft Problem
Solution
Short,
flickering
Excessive draft
or not enough
restriction
Adjust restrictor
to close more
Lifting or
ghosting*
Insufficient draft
Adjust restrictor
to open more
*If flames continue to lift or ghost after opening the
restrictor and verifying correct vent installation,
shut off the gas supply and call a qualified service
technician.
INSTALLATION FOR HORIZONTAL
TERMINATION
1. Determine the route your horizontal venting will
take. NOTE: The location of the horizontal vent
termination on the exterior wall must meet all
local and national building codes.
Snorkel terminations are available for terminations
requiring a vertical rise on the exterior of the
building. The figures follow the same installation
procedures used for standard horizontal
terminations. If installing the snorkel termination
below grade (basement applications), you must
provide proper drainage to prevent water from
entering the snorkel termination. Do not back fill
around the snorkel termination.
12”
(305 mm)
Minimum
Snorkel
TO STOVE
12”
(305 mm)
Minimum
Snorkel
Adequate
TO STOVE
Drainage
2.
Rigid vent pipes and fittings have special
twist-lock connections. Assemble the desired
combination of pipe and elbows to the
appliance adaptor with pipe seams oriented
towards the wall or floor. Twist-lock Procedure:
The female ends of the pipes and fittings have
three locking lugs (indentations). These lugs will
slide straight into matching slots on the male
end of adjacent pipes and fittings. Push the
pipe sections together and twist one section
clockwise approximately one-quarter turn until
the sections are fully locked. NOTE: Horizontal
runs of vent pipe must be supported every
three (3) feet (914 mm). Use wall straps for this
purpose.
Female
Locking
Lugs
Male
Slots
3. Attach vent pipe assembly to the stove. Set
stove in front of its permanent location to
ensure minimum clearances. Mark the wall for a
9-1/2” (241 mm) square hole (for noncombustible