Ashcroft B7 series Скачать руководство пользователя страница 8

 

Page 8 of 19 

B-Series pressure and vacuum switches use two different actuators depending on setpoint requirements. For setpoints 
between 2 and 3000 psi, the simple,  rugged diaphragm-sealed piston actuator is  used. This design features high 
reliability and  choice of actuator seal materials for virtually  every application. An optional welded design is  also 
available for setpoints up to 1000 psi for maximum reliability. This design is available in 316 SS or Monel. 

For setpoints between 4.5 and 150 inches of H2O, a large diaphragm is used for increased sensitivity with good 
choice of materials of construction. 

 

Erläuter ung,  z usätzlich ei n Hi nweis :  

6.3.2  Process adapter of pressure switch D7  

Differential pressure models use a unique, dual diaphragm-sealed piston design that features very high static 
operating pressures and small size. 

For setpoints between 1.5 and 150 inches of H2O, a large diaphragm is used for increased sensitivity with good 
choice of materials of construction. 

 

6.3.3  Process adapter of temperature switch T7 

B-Series temperature switches feature a SAMA Class II vapor pressure thermal system. This system provides quick, 
accurate response to process temperature changes with negligible ambient temperature effects. This is inherent in the 
design due to the precise relationship that exists between temperature and pressure according to the vapor pressure 
laws. A wide selection of sensing bulb and armored capillary lengths is available. The vapor pressure system design 
features small bulb sizes, making installation easy and cost-effective. 

6.3.4  Set point adjustment 

A single setpoint adjustment nut (7/8”) is located centrally at the bottom on the inside of the enclosure. 

6.3.5  Micro switch 

Standard electrical switch is SPDT, available with various electrical characteristics. Two SPDT switch elements 
mounted together are available except on variable Deadband and manual reset types. 

Microswitch Code  Electrical rating 

Single 

Dual 

VAC 

VDC 

20 

61 

15 A, 250 V 

0,4 A, 120 V 

21 

65 

5 A, 250 V 

 

22 

67 

5 A, 250 V 

2,5 A, 28 V 

23 

 

22 A, 250 V 

 

24 

64 

15 A, 480 V 

0,25 A, 250 V 

25 

 

10 A, 250 V 

10 A, 250 V 

26 

62 

15 A, 250 V 

0,4 A, 120 V 

27 

63 

15 A, 250 V 

 

28 

 

15 A, 250 V 

 

29 

 

15 A, 250 V 

 

31 

70 

1 A, 250 V 

50 mA, 60 V 

32 

68 

11 A, 250V 

5 A, 30 V 

42 

71 

1 A, 125 V 

 

50 

 

15 A, 250 V 

 

35 

 

10 A, 250 V 

0,3 A, 250 V 

Table 1: Micro switch electrical ratings 

6.3.6  Enclosure 

The Ashcroft snap action pressure switch is furnished in the flameproof NEMA 7 & 9 and ATEX Ex db and dust ignition 
protected ATEX Ex tb enclosure styles. Enclosure is epoxy coated aluminum casting or optional stainless steel 316L. 

6.4  Accessories 

Please contact the manufacturer regarding special tools and accessories.  

7  Transport 

Содержание B7 series

Страница 1: ...del B7 differential pressure switch model D7 and temperature switch model T7 for explosion risk areas pursuant to Directive 94 9 EC ATEX IEC In the following configuration B7 CN pressure switch D7 CN...

Страница 2: ...ical data 7 5 Labeling on the device 7 5 1 Labeling on the device for explosion risk areas ATEX 7 6 Construction and function 7 6 1 Overview 7 6 2 Description of function 7 6 3 Description of componen...

Страница 3: ...19 11 Removal disposal 13 11 1 Safety 13 11 2 Removal 13 11 3 Disposal 14 12 Appendix 14 12 1 Data sheet for switches B7 D7 and T7 14 12 2 EG Declaration of Conformity 15 12 3 IECEX Declaration of con...

Страница 4: ...ality 1 4 Copyright This Operating Manual may only be copied and passed on as a complete document without the special permission of the publisher 1 5 Warranty For the product described here we offer a...

Страница 5: ...al regulations for accident prevention and the operator s internal regulations regarding working operations and safety must be respected The operator is responsible for all specified servicing inspect...

Страница 6: ...32 UNF 2B socket head cap screw The base houses a range of various switch elements and an operating rod The base has three bosses at 90 apart on its side walls The two opposing bosses each contain a N...

Страница 7: ...on and function 6 1 Overview B7 pressure switch D7 differential pressure switch T7 temperature switch Figure 1 6 2 Description of function The Ashcroft pressure switch is a precision built agency appr...

Страница 8: ...This is inherent in the design due to the precise relationship that exists between temperature and pressure according to the vapor pressure laws A wide selection of sensing bulb and armored capillary...

Страница 9: ...tection against special conditions such as vibrations pulsations and pressure spikes A bracket must be installed to support the switch if the metering pipe is not able to provide adequate support Ambi...

Страница 10: ...ust be frost protected Safety notice When tightening control to pressure line always use the wrench flats or hex on the lower housing and do not twist the device itself 8 3 2 Electrical connection Tak...

Страница 11: ...pressure As received the pressure switch will normally be set to approximately 90 of the indicated range Pressurize the system to required setpoint and turn the adjustment nut until switch changes mod...

Страница 12: ...a bath at the desired setpoint temperature Optimum performance will be obtained if the bulb is fully immersed Allow five minutes for initial stabilization As received the temperature switch will norma...

Страница 13: ...nance Never use aggressive solvents Do not use high pressure water to clean the switch 10 Faults 10 1 Safety Defective or faulty switches put the operational safety and process safety of the plant at...

Страница 14: ...pose of or recycle the devices and components used in accordance with the applicable regulations 12 Appendix 12 1 Data sheet for switches B7 D7 and T7 More detailed datasheets are available direct fro...

Страница 15: ...Page 15 of 19 12 2 EG Declaration of Conformity...

Страница 16: ...Page 16 of 19 12 3 IECEX Declaration of conformity...

Страница 17: ...Page 17 of 19...

Страница 18: ...Page 18 of 19...

Страница 19: ...Page 19 of 19...