3  Use in explosion risk areas pursuant to Directive 94/9/EC (ATEX) 

3.1  B7/D7/T7 flameproof enclosure and dust ignition protection by enclosure 

Area of use: 

 

Explosion risk areas Zone 1 and 2, and 21 and 22, risk from gases and dry dust 

Permitted temperatures: 

 

Permitted ambient temperature -20°C to +60 °C. 

Permitted medium temperature in the pressure switch < 85 °C. 

Warning! With gaseous media, the device temperature may increase due to compression heat. In 
such cases, the rate of the pressure change must be regulated or the permitted temperature of the 
measuring medium reduced.

 

 

To avoid additional temperature increase, the devices should not be exposed to direct exposure to sunlight when in 
operation! 

EU design type test certification: 

The Ashcroft

®

 7XX Series Pressure & Temperature Switches comprise a cylindrical two-part enclosure, consisting of a 

base and cover, manufactured from die-cast aluminum 380 or stainless steel 316L. The cover treads into the base and 
is secured against loosening by a 10-32 UNF-2B socket head cap screw. The base houses a range of various switch 
elements and an operating rod. The base has three bosses at 90° apart on its side walls. The two opposing bosses 
each contain a ¾” NPT cable entry port while the other boss provides a facility allowing connection to different 
detecting elements retained by a mounting plate secured by six M5 x 12 hexagon head screws. The detecting 
element, when filled, secures the operating rod preventing removal and contains two venting holes that ensure that the 
interior of the enclosure is not subject to pressure greater than 2 lb/ft². 

Switch element ratings up to: 

15 A 

125/250/480 VAC 

6 A 

34 VDC 

500 mA 

125 VDC 

250 mA 

250 VDC 

Compliance with the Essential Health and Safety Requirements, with the exception of those listed in the schedule to 
EC-type examination certificate, has been assured by compliance with the following documents: 

 

This product complies with the following standards: 

IECEx 

ATEX 

EN 60079-0: 2011 Ed 6 

EN 60079-1: 2007 

EN 60079-31: 2013 

EN 60079-0: 2012 

EN 60079-1: 2007 

EN 60079-31: 2013 

 

The documentation has been filed with SIRA (see declaration of conformity). 

Labeling: 

 II 2GD  

Ex db IIC T6 Gb 

Ex tb IIIC T85°C Db IP 6X  

(Ta = -20°C to +60°C) 

 

 

Содержание B7 series

Страница 1: ...del B7 differential pressure switch model D7 and temperature switch model T7 for explosion risk areas pursuant to Directive 94 9 EC ATEX IEC In the following configuration B7 CN pressure switch D7 CN...

Страница 2: ...ical data 7 5 Labeling on the device 7 5 1 Labeling on the device for explosion risk areas ATEX 7 6 Construction and function 7 6 1 Overview 7 6 2 Description of function 7 6 3 Description of componen...

Страница 3: ...19 11 Removal disposal 13 11 1 Safety 13 11 2 Removal 13 11 3 Disposal 14 12 Appendix 14 12 1 Data sheet for switches B7 D7 and T7 14 12 2 EG Declaration of Conformity 15 12 3 IECEX Declaration of con...

Страница 4: ...ality 1 4 Copyright This Operating Manual may only be copied and passed on as a complete document without the special permission of the publisher 1 5 Warranty For the product described here we offer a...

Страница 5: ...al regulations for accident prevention and the operator s internal regulations regarding working operations and safety must be respected The operator is responsible for all specified servicing inspect...

Страница 6: ...32 UNF 2B socket head cap screw The base houses a range of various switch elements and an operating rod The base has three bosses at 90 apart on its side walls The two opposing bosses each contain a N...

Страница 7: ...on and function 6 1 Overview B7 pressure switch D7 differential pressure switch T7 temperature switch Figure 1 6 2 Description of function The Ashcroft pressure switch is a precision built agency appr...

Страница 8: ...This is inherent in the design due to the precise relationship that exists between temperature and pressure according to the vapor pressure laws A wide selection of sensing bulb and armored capillary...

Страница 9: ...tection against special conditions such as vibrations pulsations and pressure spikes A bracket must be installed to support the switch if the metering pipe is not able to provide adequate support Ambi...

Страница 10: ...ust be frost protected Safety notice When tightening control to pressure line always use the wrench flats or hex on the lower housing and do not twist the device itself 8 3 2 Electrical connection Tak...

Страница 11: ...pressure As received the pressure switch will normally be set to approximately 90 of the indicated range Pressurize the system to required setpoint and turn the adjustment nut until switch changes mod...

Страница 12: ...a bath at the desired setpoint temperature Optimum performance will be obtained if the bulb is fully immersed Allow five minutes for initial stabilization As received the temperature switch will norma...

Страница 13: ...nance Never use aggressive solvents Do not use high pressure water to clean the switch 10 Faults 10 1 Safety Defective or faulty switches put the operational safety and process safety of the plant at...

Страница 14: ...pose of or recycle the devices and components used in accordance with the applicable regulations 12 Appendix 12 1 Data sheet for switches B7 D7 and T7 More detailed datasheets are available direct fro...

Страница 15: ...Page 15 of 19 12 2 EG Declaration of Conformity...

Страница 16: ...Page 16 of 19 12 3 IECEX Declaration of conformity...

Страница 17: ...Page 17 of 19...

Страница 18: ...Page 18 of 19...

Страница 19: ...Page 19 of 19...

Отзывы: