WARRANTY:

Aseptico Inc. warrants its new products against defects in material and 

workmanship under normal and proper use, care, and maintenance 

for a period of two (2) years from date of original invoice. This two (2) 

year warranty does NOT apply nor is it extended to products that are not 

manufactured by Aseptico. These products may be covered by a separate 

limited warranty provided by the particular manufacturer, and all claims 

and questions regarding the same are to be directed to the particular 

manufacturer.

Expendable components, such as batteries, fuses, light bulbs, and tubing 

sets installed on Aseptico products are specifically excluded and have no 

warranty. Consumable goods are warranted for the stated expiration date 

of such goods.

Repair or replacement of any product(s) or part(s) under this warranty 

does not extend the term of this warranty, and such product(s) or part(s) 

shall remain covered by the unexpired portion of the warranty period, or for 

ninety (90) days from the date of return to Aseptico, whichever is later. This 

limited warranty applies only to the initial or first installation of the product 

or part.

During the specific warranty periods set forth above, Aseptico will, at its 

option, repair or replace the product(s) or particular part(s) that are found 

to be defective in either material or workmanship in part or whole. Aseptico 

shall be the sole arbiter of such action. In the event of alleged defect 

under warranty, the purchaser is to notify Aseptico’s Customer Service 

department promptly. Customer Service will provide Return Material 

Authorization (RMA) instructions, usually directing that the product be 

returned for service, shipping prepaid by the buyer or end user, to Aseptico 

or its designated and authorized warranty service center.

This warranty shall not apply to products (1) that have been subjected to 

neglect, abuse, misuse, improper installation, inadequate maintenance, or 

damage due to improper use of cleaning materials or chemicals, or non-

compliance with Aseptico’s storage, installation, operation, maintenance or 

environmental requirements; (2) that have undergone any modification or 

repair not previously authorized by Aseptico in writing, or service, repair 

or modification by or from any facility other than an authorized Aseptico 

service center or technician, or that use non-authorized software or spare 

or replacement parts; or (3) that fail due to reasonable and normal use or 

wear and tear, or materials made, furnished or specified by the buyer or 

end user.

Aseptico does not assume under this warranty any risks or liabilities 

arising from the clinical use of its products, whether or not such use 

involves coincidental utilization of products manufactured by others. 

Under no circumstances will Aseptico be liable or responsible for 

special, compensatory, incidental, consequential or punitive damages, 

lost  profits,  lost  sales,  or  loss  of  use  or  loss  of  business  opportunity 

by or through the use of the product. Aseptico’s sole and maximum 

liability with respect to the product, other than its obligations set 

forth above, shall be the total purchase price paid for the product.

Type B Equipment

Warning—Potential danger to pa-

tient or user (consult accompanying 

documents)
Dangerous Voltage

Alternating current

Handpiece - Air

Coolant

This symbol indicates that the 

waste of electrical and electronic 

equipment must not be disposed as 

unsorted municipal waste and must 

be collected separately.
Follow instructions for use.

Protective earth (ground)

Protect Against Dripping Water

Serial Number

Foot Switch

On/Off Switch

Adjustment Switches

Cavitron Connector

Fuses

SYMBOL DEFINITIONS:

IPXI

Содержание ADU-17A

Страница 1: ...ADU 17A Express Air Portable Dental System OPERATION and MAINTENANCE INSTRUCTION MANUAL...

Страница 2: ...sult if ignored CAUTION Damage to property or the environment may result if ignored NOTE Important additional information and hints Conforms To AAMI STD ES60601 1 AAMI IEC STD 62366 IEC STD 80601 2 60...

Страница 3: ...st and all uses Clean disinfect and sterilize new or repaired instruments before first use Only use sterilized handpieces and instruments during treatment Non sterile handpieces and instruments may ca...

Страница 4: ...dicator facing out Figure 2d IMPORTANT For 120V use check that the Fuse in use is a 6A medium time delay for 230V use check that the Fuse is a 4A Slo Blo type User may have to change fuses before use...

Страница 5: ...ct the Low Volume Vacuum Saliva Ejector hose to the black connector located on the front of the Tank Fig 4 High Volume Connector Low Volume Connector Water Resevoir Connector Water Supply Bottle Waste...

Страница 6: ...3 Way Air Water Syringe The Water Supply Bottle threads into the Reservoir Connector located in the upper right corner of the case To refill the Water Supply Bottle A Before removing the Bottle for re...

Страница 7: ...nnect the power cord to the Express Air Unit and plug into appropriate power source IMPORTANT Ensure that the Voltage Selector Insert is properly configured for the power source Refer to Page 4 2 FOOT...

Страница 8: ...all waterlines Fill water supply tank with bleach solution Run bleach solution through all lines Allow bleach solution to stand in lines for 10 minutes Remove water supply tank and discard bleach Flu...

Страница 9: ...heck handpiece connection for missing gasket Compressor makes a chugging sound and does not start up properly Check for sufficient power source and avoid long light grade extension cords Refer to Figu...

Страница 10: ...ting 6A at 120 VAC or 4A at 230 VAC Power Rating 800 W Operating Pressure 45 50 PSI 344 kPa Average Air Flow Pressure 35 PSI High Volume Vacuum 3 0 SCFM 4 Hg 84 9 liters min Low Volume Vacuum 1 4 SCFM...

Страница 11: ...r its designated and authorized warranty service center This warranty shall not apply to products 1 that have been subjected to neglect abuse misuse improper installation inadequate maintenance or dam...

Страница 12: ...12 P O Box 1548 Woodinville WA 98072 8333 216th Street SE Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com PRINTED IN THE U S A P N 420966 Rev G ECO 15498 04 2022...