POOL TECHNOLOGY
Maintenance
PP60 pH does not require any maintenance just regular visual check of the tubes and connections.
pH-probe
In the winter it is recommended to keep the probe in the temperature over +5°C in its airtight case so that it
does not dry out. The lifespan of the probe is 1-2 years.
Peristaltic pump
Tube inside of the pump must be changed once a year.
Replacement of the tube is done in the following way:
•
Turn the pump counterclockwise and remove it
•
Loose both ends of the tube
•
Cut the cable ties and release the tube
•
Install a new tube and secure it with new cable ties
•
Insert the tube back to the pump and grease it with a supplied grease
•
Install the pump back
Recommendations:
Aseko recommend to run filtration pump at least 6 hrs. a day so sufficient filtration is ensured.
Health and Safety
PP60 pH allows you to comply with hygiene rules for the physical and chemical requirements for pool water
quality. Install your PP60 pH indoor away from dust and high humidity and make sure all electrical
connections are secure. Do not open your PP60 pH or exchange any of the internal parts. This will damage
the electrical integrity of PP60 pH. The chemicals used with the PP60 pH must be handled in
a safe manner to prevent damage or injury. Aseko recommends you always use personal protective safety
equipment. All chemicals used for the water treatment are very aggressive. At the manipulation with them
obey the safety guidelines.