Maintenance 

PP60 pH does not require any maintenance just regular visual check of the tubes and connections.

pH-probe

In the winter it is recommended to keep the probe in the temperature over +5°C in its airtight case so that it 

does not dry out. The lifespan of the probe is 1-2 years.

Peristaltic pump

Tube inside of the pump must be changed once a year. 

Replacement of the tube is done in the following way:

Turn the pump counterclockwise and remove it

Loose both ends of the tube

Cut the cable ties and release the tube

Install a new tube and secure it with new cable ties

Insert the tube back to the pump and grease it with a supplied grease

Install the pump back

Recommendations:

Aseko recommend to run filtration pump at least 6 hrs. a day so sufficient filtration is ensured.

Health and Safety  

PP60 pH allows you to comply with hygiene rules for the physical and chemical requirements for pool water 
quality. Install your PP60 pH indoor away from dust and high humidity and make sure all electrical 
connections are secure. Do not open your PP60 pH or exchange any of the internal parts. This will damage 
the electrical integrity of PP60 pH. The chemicals used with the PP60 pH must be handled in 

a safe manner to prevent damage or injury. Aseko recommends you always use personal protective safety 
equipment. All chemicals used for the water treatment are very aggressive. At the manipulation with them 
obey the safety guidelines.