POOL TECHNOLOGY

First start

 

The first start of the PP60 pH should be in the fresh water without any additional chemicals. Turn on the 

PP60 pH by plugging it into a power socket.

You can move in the settings by the key MODE, the values displayed for particular items can be set by the  

keys + and -. Press OK to confirm. Return to default screen by press MODE several times. 

Don't forget to enter 

2. Pool volume

 in m

3

.

1. By pressing the 

4. Manual dose 

you can test the tubes for leaks. During the manual test   pH-liquid 

should moving through the tubes. When test is over liquid should not fall back to canister. 

2. Select the 

1. Required values

 and setup the required pH-value and press OK

3. Select what type of pH you want 

5. pH+ / pH-

.

4. After the start of the filtration pump check if water flows to the probe.

5. Now is the time for the probe calibration. Measure teh pH-value of the pool water by the manual 

tester. In case the value measured by the regulator differs from that one found by the manual 
measurement, make the correction in the item 

3. Calibration

 and confirm by OK. To the operation 

mode you return by the repeated pressing MODE.