General safety information

This user manual contain basic information that should be observed during assembly, start-up, 
operation, and maintenance. Therefore, this user manual must be read by installers and operators 
prior to assembly and start/up, and must be accessible to every user of this unit. Additionally, 
all further safety information in this document absolutely must be observed. Read and follow all 
instructions. In order to minimize the danger of injury, do not allow children to use this product. 
Hazards from non-compliance with safety information. Non-compliance with safety information 
can result in hazards to persons, the environment, and the equipment. Non-compliance with safety 
information will result in a forfeit of any potential right to damage compensation.  

Insuffi cient personnel qualifi cation

Hazards in the event of insuffi  ciently qualifi ed personnel, potential consequence: Injury, heavy material 
damage.

•  The system operator must ensure compliance with the required qualifi cation level.
•  Any and all work may only be performed by correspondingly qualifi ed personnel.
•  Access to the system must be prevented for insuffi  ciently qualifi ed persons, e.g. via access codes 

and passwords.

Potential overdosing of chemical agents

Despite PP60 pH® comprehensive safety functions, it is possible that a probe failure and other errors 
could lead to an overdosing of chemical agents. Potential consequence: Injury, heavy material damage.

•  Design your installation such that uncontrolled dosage is not possible in the event of a probe failure 

or other errors, and/or such that uncontrolled dosage is recognized and halted before damage is 
incurred. 

•  Uncontrolled overdose of chemicals can cause harm to health and property. Even though the device 

contains a number of security elements can not be ruled out that in case of failure of the measuring 
probes, or the whole device may result in overdose of chemical agents. Install the equipment so 
that uncontrolled overdose of chemicals was not possible and that uncontrolled overdose has been 
detected in time before causing any harm. It is necessary to use chemicals in such quantities that an 
overdose will not cause dangerous concentration of chemical agents. Do not use chemicals in too 
large packages or with too high concentration.

Gaseous chlorine produced from dosing in standing water if dosing 

outputs are not closed via the fi lter pump

If the fl ow switch is stuck or experiences another error, there is a risk of dosing into standing water. 
Poisonous chlorine gas can be yielded when sodium hypochlorite and pH minus come together.

Non compliance with informational text

There is a great deal of informational text indicating hazards and their avoidance. Not observing informational 
text may lead to hazards. Potential consequence: gravest degree of injury, heavy material damage.

•  Read all informational text carefully.
•  Cancel the process if you are unable to exclude all potential hazards.

Содержание 13260

Страница 1: ...USER S MANUAL PP60 pH EN PERISTLATIC PUMP FOR pH REGULATION www asekopool com...

Страница 2: ...osing of chemical agents Potential consequence Injury heavy material damage Design your installation such that uncontrolled dosage is not possible in the event of a probe failure or other errors and o...

Страница 3: ...s wrong If disinfection is enabled before the pH value is stable in the ideal range of 7 0 to 7 4 then it may lead to heavy overdosing of chlorine or bromine Potential consequence Injury heavy materia...

Страница 4: ...pump 12117 Injecrion valve 12005 Suction tube weight 12023 Dowels and screws PE Tube 1 4 6 35 mm transparent 12008 PP60 pH 13260 pH probe Long Life 12012 Probe wrench 13046 Measuring Water Valve 2 pc...

Страница 5: ...CZ 5 Accessories Original aseko chemicals Vlepovac z tka se z vitem 1 4 12134 pH Buffer 7 00 12065 pH MINUS 20l 12130 pH MINUS 5l 12131 pH PLUS 20l 12120 pH PLUS 5l 12136 Fotometr 13076...

Страница 6: ...dry and dust free environment with temperature ranging from 5 C to 40 C To mount the device use the mounting holes that are accessible after opening the front cover of the device To mount the device u...

Страница 7: ...connector ring After probes have been inserted slightly tightened and connectors have been connected PP60 pH is ready for connection to the water system of your pool WARNING Only hand tighten the pro...

Страница 8: ...f delivery The use of scissors or tongs deforms the tube end and leads to leaks WARNING Only hand tighten Do not use tongs or any other tools 1 To ensure tightness of joints cut the tube at 90 angle U...

Страница 9: ...OUTLET CAN BE REALISED 1 downstream of filtration 2 to non pressure overflow tank TO POOL Heating FROM POOL Sampling point for callibration POOL WATER INLET IN IN OUT OUT Besgo Coagulation mixer Max...

Страница 10: ...ush the PE tube through the cap Select the tube distance so that the tube reaches the canister bottom and can be connected to the pump as straight as possible A long tube in the canister would bend an...

Страница 11: ...CZ 11 Max 8 m Max 8 m Max 2 m TO POOL Heating FROM POOL Besgo Coagulation mixer Sampling point for callibration...

Страница 12: ...shows the dose in ml Press the OK button to start manual dosing and monitor the process of the OK button to start manual dosing and monitor the process of the OK dosing liquid in the transparent tubes...

Страница 13: ...inlet to probes and furthermore from the water outlet from probes to the closing valve Check condition of the extraction valve and the closing valve and their seals for being clogged and their closed...

Страница 14: ...Lubricate the new hose with the supplied special grease Insert the lubricated hose into the cassette Place the cover cassette back on PP60 pH and turn it clockwise to lock it Use new nuts which are pa...

Страница 15: ...CZ 15...

Страница 16: ...www asekopool com PP60 pH USER S MANUAL EN...

Отзывы: