Initial start
Power connection
PP60 pH is switched on by connecting to the power supply. PP60 pH power
supply must be connected together with the power supply of the circula-
tion pump. Switching off the circulation pump must switch off the PP60 pH,
otherwise inaccurate measurement and incorrect dosing would occur. PP60
pH is to be installed in the pool with clean water without any pool chemicals.
When the device is switched on by connecting to the mains, the actual mea-
sured pH value lights up on the display.
Initial start setup
Below the display is a list of menu items. To move in the list use the MODE
button. The values displayed are adjusted with the + and - buttons. The set
value must be confi rmed with the OK button. Then return to the operating
mode by pressing the MODE button repeatedly.
To set up the device for the fi rst time, follow the procedure below:
1.
In the control menu, select
2. Pool volume
. Enter the volume of your
pool in m³.
2.
In this step, we advise testing the connections tightness. In the control
menu, select
4. Manual dose
. The display shows the dose in ml. Press
the
OK
button to start manual dosing and monitor the process of the
OK
OK
dosing liquid in the transparent tubes up to the inlet to the circulation
pipe. When the liquid reaches the circulation pump, end the manual
dosing by pressing
OK
. Check whether the liquid in the tube is not falling
back. If the liquid is falling back check the leakage of PE Tube.
3.
Select
1. Required values
, set the desired pH value to which you want
to regulate
4.
Select
5. pH + / pH-
set which reagent you want to dose into the pool.
5.
After starting the circulation pump, check that the water fl ows to the pH
probe.
6.
In operation, there may be a diff erence between the measured and the
actual pH value in the water. Calibration can be performed in two ways:
•
Remove the probe from the device. The probe must remain connected to
the device with a cable. Rinse the probe with clean water and wipe. Dip it
in calibration buff er 7.0. After stabilizing the value, enter the value
in
3. Calibration
, which will perform the calibration.
•
Measure the pH value directly in the pool water using a photometer.
Enter the manually measured value in
3. Calibration
.
7.
Press the
MODE
button repeatedly to return to operating mode.