Basic Troubleshooting Steps
Problem Possible
Cause
Remedy
Section
Two-inch switch out of
adjustment
Adjust two-inch switch
3.8
Lift car will not go
more than 10" off
the ground
Lift is in transport mode
Set the upper height
knob properly per the
Operating Manual
N/A
Lift car does not
stop
automatically at
the upper landing
Upper height knob is not set
correctly
Set the upper height
knob properly per the
Operating Manual
N/A
Upper stop switch failure
Replace upper stop
switch
3.8
Upper stop mechanism is out of
adjustment
Adjust upper stop
mechanism
3.8
Motor runs but lift
car does not
elevate
Hydraulic fluid level is low
Fill hydraulic fluid
reservoir
2.1
Break in hydraulic circuit
Repair break and fill
hydraulic fluid reservoir
2.1
Directional valve stuck open
Replace directional
valve
3.14
Lift car is overloaded
Reduce load on lift car
until load is equal to or
less than the rated
load
N/A