background image

 

MST Instance 

parameters can be modified on the following two screens. 

 

 

 

 

 

 

 

77 

Asante IntraCore IC39240/480 

User’s Manual

 

 

Содержание IntraCore 39240

Страница 1: ...IntraCore 39240 480 Layer 2 Gigabit Ethernet Switch User s Manual...

Страница 2: ...oduct design or design concept may be copied or reproduced in whole or in part by any means without the express written consent of Asante Asante and IntraCore are registered trademarks and the Asante...

Страница 3: ...afety Overview 14 2 1 2 Recommended Installation Tools 15 2 1 3 Power Requirements 15 2 1 4 Environmental Requirements 15 2 1 5 Cooling and Airflow 15 2 2 Installing into an Equipment Rack 15 2 2 1 Eq...

Страница 4: ...eleting Entries 33 Chapter 5 Managing the System and Configuration Files 33 5 1 Managing the System 34 5 1 1 Setting the System Clock 34 5 1 2 Specify the Hostname 35 5 1 5 Test Connections with Ping...

Страница 5: ...Access List 52 Chapter 7 VLAN Configuration 53 7 1 Creating or Modifying a VLAN 53 VLANS can be configured using the following commands 54 7 2 VLAN Port Membership 54 7 2 1 configuring vlan ports 54...

Страница 6: ...ng 66 Chapter 10 CLI Commands 109 Appendix A Basic Troubleshooting 138 Appendix B Specifications 139 Appendix C FCC Compliance and Warranty Statements 144 C 1 FCC Compliance Statement 144 C 2 Importan...

Страница 7: ...erformance by segregating them into separate broadcast domains with IEEE 802 1Q compliant VLANs and provide multimedia applications with multicast switching and CoS services The system can operate as...

Страница 8: ...om Normal Exec Level RADIUS Authentication TACACS Authentication 802 1x Port Authentication HTTPS Port Security IP Filtering Username admin Password Asante Username admin Password Asante Disabled Disa...

Страница 9: ...imits Disabled Port Trucking LACP all ports Disabled Broadcast Storm Protection Status Broadcast Limit Rate Enabled all ports 500 packets per second Spanning Tree Protocol Status Disabled Address Tabl...

Страница 10: ...RP 192 168 0 1 255 255 255 0 0 0 0 0 Client Disabled Enabled Multicast Filtering IGMP Snooping Disabled System Log Remote logging Memory log Flash log Disabled Enabled Enabled SNTP Clock Synchronizati...

Страница 11: ...Descriptions The following section describes the front and back panels of the IntraCore IC39240 480 Series switches The front panel of the IntraCore IC39240 480 contains the following power and port...

Страница 12: ...39480 Front Panel Ethernet ports Mini GBIC ports 39480 Rear Panel 12 Asante IntraCore IC39240 480 User s Manual...

Страница 13: ...mmand Line Interface CLI in order to access several different command modes Entering a question mark at each command mode s prompt provides a list of commands 1 5 1 Console Interface Support for local...

Страница 14: ...to protect the switch from damage Note This information is a guideline and may not include every possible hazard Use caution when installing this switch Only trained and qualified personnel should be...

Страница 15: ...Hz 2 1 4 Environmental Requirements Install the switch in a clean dry dust free area with adequate air circulation to maintain the following environmental limits Operating Temperature 0 to 40 C 32 to...

Страница 16: ...Be sure that no obstructions such as other equipment or cables block airflow to or from the vents of the switch Clearance In addition to providing clearance for ventilation ensure that adequate cleara...

Страница 17: ...he switch is connected to the network it can be configured for management capabilities see the following chapters for information on configuration 2 5 1 10 100 1000BaseT Ports Cabling Procedures The 1...

Страница 18: ...ue White 5 1 White Blue 6 3 Green White 7 4 White Brown 8 4 Brown White 2 5 2 Gigabit Ethernet Ports Cabling Procedures Cabling requirements for the optional hardware modules depend on the type of mod...

Страница 19: ...UTP cable up to 100 m 328 1 When attaching a workstation to the switch a standard straight through CAT5 cable may be used even when the workstation is attached via a patch panel No crossover cable is...

Страница 20: ...Attach a straight through serial cable between the RS232 console port and a COM port on the PC 9 Set up a HyperTerminal or equivalent terminal program in the following manner a Open the HyperTerminal...

Страница 21: ...w that terminal is set up correctly power on the switch The boot sequence will display in the terminal After connecting to the console you will be asked for a password The initial default password for...

Страница 22: ...ed to them By default each switchport belongs to VLAN 1 Use the following instructions to configure an IP address to the switch Follow the steps below to change the switch s IP address 1 Connect to th...

Страница 23: ...g Switch save Important To retain configuration changes after a system reload you must save changes made in running configuration From the privileged level configurations can be saved using the save c...

Страница 24: ...ystem prompt provides a list of commands available for each command mode Document Conventions Command descriptions use the following conventions Vertical bars separate alternative mutually exclusive e...

Страница 25: ...ew all the commands that start with that letter with no space between the letter and the question mark Please note that there is no help on the arguments after a command is typed Use logout to logout...

Страница 26: ...nostic clear Command to clear switch configuration or statistics configuration Enter into global configuration mode copy Upload file from switch to host or download file to switch from host exit Exit...

Страница 27: ...commands To exit global configuration command mode and return to privileged EXEC mode use one of the following commands Command Purpose exit Exits global configuration mode and returns to privileged E...

Страница 28: ...mode green eth Configure Green Ethernet enable or disable Switch Config From global configuration mode you can access three additional configuration modes Use the interface command to access its conf...

Страница 29: ...ol Configure storm control on a port rmon counter Configure RMON counter capability on a port set Configure an IGMP router port spanning tree Configure port spanning tree vlan Configure VLAN propertie...

Страница 30: ...cause it reminds you which keywords or arguments are applicable based on the command keywords and arguments you already have entered Example of Context Sensitive Help The following example illustrates...

Страница 31: ...contents delete Remove the ACL entry enable Enable the ACL entry disable Disable the ACL entry set Set ACL entry contents Switch Config access list name acl_1 4 5 Using CLI Command History The CLI use...

Страница 32: ...g Entries Scrolling Down a Line or a Screen Redisplaying the Current Command Line Transposing Mistyped Characters Controlling Capitalization 4 6 1 Moving Around on the Command Line Use the following k...

Страница 33: ...so that you may modify the command if necessary You may also enter a question mark to obtain a list of commands that begin with that set of characters Do not leave a space between the last letter ent...

Страница 34: ...The IntraCore 39240 480has a battery backed system clock that is accurate even after a system restart To manually set the system clock complete the following commands in privileged configuration mode...

Страница 35: ...r device on the network from the switch Command Purpose ping address Send an ICMP echo message to a designated host for testing connectivity 5 1 3 Enable the System Log The IntraCore 39240 480 sends s...

Страница 36: ...ing the commands you have entered Precede a comment with an exclamation point 5 2 2 Copying Configuration Files to a Network Server You can copy configuration files from the switch to a file server us...

Страница 37: ...onfig command loads the configuration files into the switch as if you were typing the commands in at the command line The switch does not erase the existing running configuration before adding the com...

Страница 38: ...mage from the server in case of system image file corruption To save the system image file of the switch to a TFTP server use one of the following commands in EXEC mode Command Purpose copy system_ima...

Страница 39: ...the SNMP manager to a specific event on the network Such events include improper user authentication restarts link status up or down closing of a TCP connection or loss of connection to a neighboring...

Страница 40: ...bridge on the network communicate with each other using special packets of data called Bridge Protocol Data Units BPDUs The information exchanged in the BPDUs allows the bridges on the network to do...

Страница 41: ...or more ports have the same path cost the STP selects the path with the highest priority the lowest numerical value By changing the priority of a port it can be more or less likely to become the root...

Страница 42: ...ge port will be in the RSTP initialization state and will send out the RSTP BPDUs with the operating status of edge port set to TRUE If the edge port starts receiving the BPDUs it will change the oper...

Страница 43: ...Purpose spanning tree port force p2plink enable ports 1 2 Set link type of port 1 2 to point to point By default the link type is determined from the duplex mode of the interface a full duplex port i...

Страница 44: ...cost are determined by the operating port speed For ports operating in 1000Mb speed the path cost is 20000 For ports operating in 100Mb speed the path cost is 200000 For ports operating in 10Mb speed...

Страница 45: ...For port priority the range is 0 240 in increments of 16 the default is 128 The lower the number the higher the priority 45 Asante IntraCore IC39240 480 User s Manual...

Страница 46: ...was possible that IP addresses would run out and routing tables would be overwhelmed Thus the Classless Inter Domain Routing CIDR addressing scheme was created CIDR replaces the older process of assi...

Страница 47: ...local addresses as MAC addresses because the Media Access Control MAC sub layer within the data link layer processes addresses for the layer To communicate with a device on Ethernet you first must de...

Страница 48: ...IGMP query timeout and the maximum query response time 6 2 1 IGMP Overview The Internet Group Management Protocol IGMP manages the multicast groups on a LAN IP hosts use IGMP to report their group mem...

Страница 49: ...rier Modifying the IGMP Host Query Message Interval Multicast switches elect a designated switch for the LAN subnet The designated switch is the one with the highest IP address The switch is responsib...

Страница 50: ...lower value than those with higher priority values The last match determines whether the software accepts or rejects the address In case of multiple matches the match in IP mode takes precedence over...

Страница 51: ...c from 192 168 123 254 and allow all other traffic to be forwarded Switch Config access list name acl_ip add priority 1 Switch Config access list name acl_ip set ip mode srcip 192 168 123 254 255 255...

Страница 52: ...y 1 Switch Config access list name acl_tcp_dst_smtp set ip mode l4port dst port from 25 to 25 Switch Config access list name acl_tcp_dst_smtp set portlist 7 Switch Config access list name acl_tcp_dst_...

Страница 53: ...ing The following shows the commands available to configure VLAN s Switch Config vlan add Create a new VLAN delete Remove a existed VLAN port Configure 802 1Q port parameters for VLANs lag Configure l...

Страница 54: ...ents Use the following commands beginning in configuration mode to assign an IEEE 802 1q trunk port To create 3 vlans 2 3 4 with vlan 2 untagged port members 1 2 3 4 vlan 3 untagged port members 6 7 8...

Страница 55: ...MBER Enter the interface number to access the interface configuration mode Vlan participation This command designates the interface to be a member of a vlan Use the no form of this command to reset to...

Страница 56: ...he untagged frames are classified to the trunk port s native VLAN the VLAN whose VID matches the port s PVID The trunk port also sends out the frames as untagged for the native VLAN and tagged for oth...

Страница 57: ...ng algorithm There are 2 methods to schedule a packet to be transmitted from the switch strict priority and weighed round robin In strict priority the packet with the highest priority will be sent fir...

Страница 58: ...0 7 and 4 internal queues Each packet can be assigned a priority based on which port it comes in 802 1P header or IP precedence DSCP in IP header if the packet is an IP packet The OQS configurations...

Страница 59: ...to the packet by the switch 8 2 4 IP Based QOS The priority of an IP packet can be assigned based on the IP Precedence or DSCP value To set IP Precedence QOS use the following command in EXEC mode Co...

Страница 60: ...raffic shaping for outbound traffic on an interface use the following command in interface configuration mode Command Purpose Switch config interface 5 Go to interface 5 Switch interface 5 rate limit...

Страница 61: ...plement them refer to the chapters specific to that function At your web browser enter the IP address for the switch to launch the GUI Depending on settings you may receive a certificate error message...

Страница 62: ...configure the switch From this panel you can access the following screens System Port Management VLAN Management Spanning Tree Multicast Security QoS SNMP LLDP Admin Statistics Help Logout The followi...

Страница 63: ...irst system screen up a name and location for the switch can be added A system contact can also be entered You can also view the Hardware Version Boot Version Firmware Version Build Date and the MAC A...

Страница 64: ...IP addresses to network interfaces Doing so enables the interfaces and allows communication with hosts on those interfaces using IP Associated with this task are decisions about subnetting and maskin...

Страница 65: ...ast When multiple networks are connected to the Internet the traditional classified addressing scheme could cause you to run out of IP addresses The usual way of assigning IP addresses uses the prefix...

Страница 66: ...Time Setting Use the Time Setting page to set the time zone or local time for the switch Daylight savings can also be enabled Click the Save Settings button when done 66 Asante IntraCore IC39240 480 U...

Страница 67: ...9 2 4 System Green Ethernet Green Ethernet is a power saving technology that allows the switch to save power when Ethernet is not being actively used 67 Asante IntraCore IC39240 480 User s Manual...

Страница 68: ...Management section displays assorted settings for each port Port Management Port Config Specific Port Settings can be made on a per port basis When a port number is clicked the subscreen appears 68 As...

Страница 69: ...displayed on this screen The system LACP Priority can be set here By clicking on a port number a subscreen for each port is available Port Management LACP Property Port Settings for each port can be...

Страница 70: ...k on a group number to set the groups properties Port Management LAG Group Each Group Once a link aggregation group is specified the screen below can be used to add ports to the group 70 Asante IntraC...

Страница 71: ...N segment VLANs are usually associated with IP subnetworks For example all the end stations in a particular IP subnet belong to the same VLAN Traffic between VLANs is assigned LAN port VLAN membership...

Страница 72: ...VLAN SETTINGS With a vlan selected ports can be marked as tagged or untagged Lover on the screen LAG groups can also be tagged or untagged Click Save Settings when done 72 Asante IntraCore IC39240 48...

Страница 73: ...ID in required to force the port to respond to a particular VLAN Becoming a member of a VLAN is only the start The port PVID must be changed to cause it to respond only to the desired VLAN Various fil...

Страница 74: ...00 Mbps port is the result of the equation Path cost 1000 LAN speed in Mbps Therefore for 10 Mbps ports the default port path cost is 100 For 100 Mbps ports it is 10 To allow for faster networks the p...

Страница 75: ...ation Path cost 1000 LAN speed in Mbps Therefore for 10 Mbps ports the default port path cost is 100 For 100 Mbps ports it is 10 To allow for faster networks the port path cost for a 1000 Mbps port is...

Страница 76: ...MSTP Multiple Spanning Tree Protocol can be enabled on this page Individual Port properties can be manipulated at this screen 76 Asante IntraCore IC39240 480 User s Manual...

Страница 77: ...MST Instance parameters can be modified on the following two screens 77 Asante IntraCore IC39240 480 User s Manual...

Страница 78: ...9 6 Multicast Static multicast settings can be set Port by port participation can be controlled 78 Asante IntraCore IC39240 480 User s Manual...

Страница 79: ...is responsible for sending IGMP host query messages to all hosts on the LAN By default the designated switch sends IGMP host query messages every 60 seconds in order to keep the IGMP overhead on hosts...

Страница 80: ...Port Security Each port can be listed individually or a table can be displayed using the Show Table button Access control lists can be established using this screen 80 Asante IntraCore IC39240 480 Us...

Страница 81: ...802 1X can be enabled on a per port basis Radius server can be identified at this screen A secret key can be created and the port can be altered 81 Asante IntraCore IC39240 480 User s Manual...

Страница 82: ...TACAS and Storm Control are available on the next screens 82 Asante IntraCore IC39240 480 User s Manual...

Страница 83: ...can be used to enter a list of IP addresses to limit the availability of switch Management Auto DoS provides protection from a variety of denial of service type of threats 83 Asante IntraCore IC39240...

Страница 84: ...9 8 QoS Quality of service settings allow various protocols to be selected to protect functions that require real time performance and limit other traffic 84 Asante IntraCore IC39240 480 User s Manual...

Страница 85: ...d on this page There are eight queues available numbering 0 7 Click on the Mode selector to choose DSCP Then settings will be available to assign DHCP codes to the eignt queues 85 Asante IntraCore IC3...

Страница 86: ...802 1P priory is supported to four queues Each priority level can be assigned to one of the four queues 86 Asante IntraCore IC39240 480 User s Manual...

Страница 87: ...Port based QoS allows the priority for each port to be manually set Click the Update button when done to save changes 87 Asante IntraCore IC39240 480 User s Manual...

Страница 88: ...Rate Control allows traffic shaping for each port An ingress rate limit can also be set 88 Asante IntraCore IC39240 480 User s Manual...

Страница 89: ...The IntraCore IC39240 480 supports SNMPv1 v2 and v3 The SNMPv3 protocol has improved the authentication access control and security methods Use the following screens to set the read write access and t...

Страница 90: ...SNMP Continued 90 Asante IntraCore IC39240 480 User s Manual...

Страница 91: ...9 10 LLDP 91 Asante IntraCore IC39240 480 User s Manual...

Страница 92: ...92 Asante IntraCore IC39240 480 User s Manual...

Страница 93: ...creen that can be used to change the password Remember to click Save Settings when done L2 Table makes available MAC addresses and lists the port they are associated with Aging time can also be specif...

Страница 94: ...resses can be added using this screen Dynamic ARP is the screen that allows aging time and trusted ports to be set on a per port basis Click Save Setting when done 94 Asante IntraCore IC39240 480 User...

Страница 95: ...checking the ingress mirror or egress mirror for the port Next select the port to mirror the information to Admin Timeout allows the timeout in seconds to be set before the management session is termi...

Страница 96: ...96 Asante IntraCore IC39240 480 User s Manual...

Страница 97: ...ADMIN Continued assorted administration functions are controlled using the next several screens 97 Asante IntraCore IC39240 480 User s Manual...

Страница 98: ...98 Asante IntraCore IC39240 480 User s Manual...

Страница 99: ...99 Asante IntraCore IC39240 480 User s Manual...

Страница 100: ...100 Asante IntraCore IC39240 480 User s Manual...

Страница 101: ...Cable diagnostic a cable test that can be run for each port 101 Asante IntraCore IC39240 480 User s Manual...

Страница 102: ...DHCP Relay DCP Option 82 these screens control the relay of DHCP information from a server VLANS can also be specified to receive DHCP information 102 Asante IntraCore IC39240 480 User s Manual...

Страница 103: ...9 12 Statistics RMON information and settings are controlled using the next screens General counters and timers are also displayed 103 Asante IntraCore IC39240 480 User s Manual...

Страница 104: ...104 Asante IntraCore IC39240 480 User s Manual...

Страница 105: ...105 Asante IntraCore IC39240 480 User s Manual...

Страница 106: ...106 Asante IntraCore IC39240 480 User s Manual...

Страница 107: ...9 13 Help General help is available for many screens 107 Asante IntraCore IC39240 480 User s Manual...

Страница 108: ...9 14 Logout Use this screen to logout and close the session 108 Asante IntraCore IC39240 480 User s Manual...

Страница 109: ...s level is Command Prompt Switch Global Config Mode This mode permits the operator to make modifications to the running configuration General setup commands are grouped in this mode From the Global Co...

Страница 110: ...ode Privileged Mode e g Switch cable diag port 1 10 3 2 clear 10 3 2 1 clear arl This command is used to clear ARL table entries Format clear arl Mode Privileged Mode 1 clear arl dynamic This command...

Страница 111: ...switch to host or download file to switch from host 10 3 4 1 copy nvram_config This command is used to backup switch configuration Format copy nvram_config tftp A B C D file filename Mode Privileged M...

Страница 112: ...3 show qos advanced This command display qos advanced mode information show qos advanced mode This command display mode of qos Format show qos advanced mode Mode Privileged Mode show qos advanced dscp...

Страница 113: ...sed to display port RX and TX Format show interface history port ID Mode Privileged Mode 2 show interface statistics This command is used to display port summary statistics Format show interface stati...

Страница 114: ...h interface Format show port port index port ID Mode Privileged Mode show port all This command is used to display all switch interface Format show port all Mode Privileged Mode 10 3 11 11 show port s...

Страница 115: ...21 Format show spanning tree interface port port ID Mode Privileged Mode show spanning tree interface all This command display all switch interface Format show spanning tree interface all Mode Privil...

Страница 116: ...command is used to display the value of trap flags that apply to the switch Format show trapflags Mode Privileged Mode 10 3 11 21 show vlan This command is used to display vlan configuration 1 show v...

Страница 117: ...lan This command is used to configure vlan 10 4 2 1 vlan add This command is used to create a new vlan vlan add number This command enter a vlan ID Format vlan add number vlan ID Mode Global Config vl...

Страница 118: ...onfig vlan port ports protected This command is used to configure protected ports Format vlan port ports protected enable disable Mode Global Config vlan port ports pvid This command is used to config...

Страница 119: ...This command is used to specify advertised interval in seconds Format lldp adv interval 5 32768 Mode Global Config 10 4 6 4 lldp fast startcnt This command is used to specify advertised interval in s...

Страница 120: ...ogging target console enable disable Mode Global Config 4 log logging target server This command is used to specify console log notify level Format log logging target server name WORD enable disable M...

Страница 121: ...h config monitor des 1 probetype ingress src 2 8 3 monitor des port ID probetype egress This command configures port monitor probetype as egress traffic Format monitor des port ID probetype egress src...

Страница 122: ...relay vlan vlan ID add Mode Global Config network dhcp relay vlan vlan ID remove This command enters a vlan which will be disable dhcp relay option82 Format network dhcp relay vlan vlan ID remove Mode...

Страница 123: ...4 14 5 port all rate limit Configure rate limit value on all ports 1 port all rate limit egress This command specifies egress rate limit Format port all Rate Limit egress value Mode Global Config 31 2...

Страница 124: ...rmat qos qos advanced none Mode Global Config 32 10 4 15 2 qos cos This command configures 802 1p priority queue mapping Format Qos cos priority 0 7 queue 1 4 Mode Global Config 10 4 15 3 qos dscp Thi...

Страница 125: ...p query resinterval 0 200 Mode Global Config 7 set igmp robustness This command specifies robustness variable Format set igmp robustness 1 20 Mode Global Config 8 set igmp router port This command spe...

Страница 126: ...y add community name group group name mgmt ip ip addr Mode Global Config 2 snmp community delete This command deletes a community Format snmp community delete community name Mode Global Config 10 4 17...

Страница 127: ...Global Config 10 4 18 3 sntp server 1 sntp server enable This command enables sntp server Format sntp server enable Mode Global Config 2 sntp server ipaddr This command sets sntp server IP address For...

Страница 128: ...1 40 Mode Global Config 10 4 110 6 spanning tree port 1 spanning tree port all This command specifies RSTP capability for all ports Format spanning tree port all enable disable Mode Global Config 2 s...

Страница 129: ...Format Spanning Tree mst vlan MST ID vlan list delete Mode Global Config 38 3 spanning tree mst bridgepri This command configures bridge priority for a MST instance Format spanning tree mst bridgepri...

Страница 130: ...CH 10 4 23 1 access list name WORD add This command creates a new access list Format access list name WORD add priority 1 65535 Mode Global Config 10 4 23 2 access list name WORD action 1 access list...

Страница 131: ...e ACL entry Format access list name WORD deletes Mode Global Config 10 4 23 5 access list name WORD enable disable This command enables disables the ACL entry Format access list name WORD enable disab...

Страница 132: ...ode Global Config 10 4 24 arp Commands Note This commands only support on GG24 GIGABIT PORTS WITH 2 SHARED MINI GBIC SLOTS G44 GIGABIT PORTS WITH 4 SHARED MINI GBIC SLOTS L2 MANAGEMENT SWITCH 10 4 24...

Страница 133: ...k prevention Format dos ports smurf enable disable Mode Global Config 43 2 dos ports ping flooding This command enables and disables ping flooding type attack prevention Format dos ports ping flooding...

Страница 134: ...5 6 2 configure notifications Enable disable notification form the agent Format lldp notification enable disable Mode Interface Config 10 5 6 3 Configure med notifications Configure wether or not MED...

Страница 135: ...port security lock mode none static Mode Interface Config port security lock mode dynamic This command enable limited dynamic lock mode and specify maximin learning entries for limited dynamic lock m...

Страница 136: ...16 set igmp router port command This command specifies igmp router port Format set igmp router port ebable disable Mode Interface Config 10 5 17 spanning tree command 10 5 17 1 spanning tree cost This...

Страница 137: ...10 5 18 VLAN command 10 5 18 1 vlan participation This command join or leave a vlan 1 vlan participation exclude This command leave a vlan Format vlan participation exclude vlan id Mode Interface Conf...

Страница 138: ...2 6 Connecting to the Network for more information The GBIC Link LED is not lit Check the GBIC connector Make sure the cables are inserted correctly with the Transmit Tx connector on one side of the...

Страница 139: ...Console port Status Indicators Power Operating status of the unit 2 1 LEDs for port link activity speed Performance Specifications Forwarding modes Store and forward Bandwidth 96 48 Gbps non blocking...

Страница 140: ...m Log RFC 1157 SNMP v1 v2c RFC 768 UDP UDP Relay RFC 854 859 Telnet RFC 951 BOOTP RFC1757 RMON RFC 1643 Ethernet Interface MIB RFC 1493 Bridge MIB RFC 1534 DHCP BOOTP RFC 2865 2866 RADIUS Port Mirrori...

Страница 141: ...ifications Command Line Interface Web Telnet IEEE 802 1 Q VLAN IEEE 802 1p CoS IEEE 802 1D Spanning Tree IEEE 802 1v VLAN IEEE 802 1w Rapid Spanning Tree IEEE 802 1s Multiple Spanning Tree IEEE 802 3a...

Страница 142: ...r Internal auto switching 100 240 VAC 50 60 Hz Operating Temperature 0 C to 40 C 32 F to 104 F Storage temperature 20 to 70 C 4 to 158 F Relative Humidity 10 to 90 non condensing Storage humidity 95 m...

Страница 143: ...is warranty is exclusive and is limited to the original end user purchaser with the original warranty card only This warranty shall not apply to secondhand products or to products that have been subje...

Страница 144: ...should never be placed near or over a radiator or heat register This product should not be placed in a built in installation unless proper ventilation is provided 8 This product should be operated fro...

Страница 145: ...mited to cables brackets and fasteners included with the covered product nor to any discontinued product i e product purchased more than thirty days after Asante has removed such product from its pric...

Страница 146: ...ng 58 Quality of Service 57 rate limit 60 SNMP Configuration GUI 89 traffic shaping interface 60 VLAN 71 weighted fair queuing 57 Connecting console 13 20 network 17 PC 22 power 17 Console baud rate 2...

Страница 147: ...nfiguring 58 examples 59 monitoring 59 Quality of Service configuration 57 priority queuing 58 traffic shaping 60 weighted fair queuing 57 Rapid Spanning Tree edge port 43 link type 43 port path cost...

Страница 148: ...148 Asante IntraCore IC39240 480 User s Manual bandwidth 57 configuration 57 monitoring 57 58 59 60...

Отзывы: