65
3
Fit an O-Ring onto the module end
face on the permeate side. Pour clean
water
(e.g.,
permeate)
on
the
permeate end of the module until
water completely covers the surface.
4
1) Gradually pressurize the module
using the air scrubbing unit.
2) Observe for a continuous stream of
bubbles that would identify a
leaking membrane.
3) Repair/isolate
the
leaking
membrane by inserting a special
stainless steel brad into the leaking
fiber's end.
Note:
Ensure that the air pressure during
testing
is
below
200
kPa.
Membrane may be dried with
higher pressures.
Repair work is easier at lower
pressures. Adjust air valve as
required.
5
Insert (hammer in) the nail to a depth
of about 1cm.