Once the pressure reading of PIA has stabilized, close the air supply valve for leak testing
(AV-11).
(6)
Hold the pressure for 3 minutes and check for pressure decay.
(7)
Pressure decrease of 15 kPa (5 kPa/min) or more: leak present
Pressure decrease of less than 15 kPa (5 kPa/min): no leak
(8)
If there is a leak, an air leak test is conducted to identify the modules that have a leak.
Figure 17 Step 2 for PDT